Model: (14-01) Touchless -Vehicle Exhaust Extraction Arms- up to 43 feet long-600 to 1500 CFM


“Ready to install and use” FLEXI Extraction Arms for vehicle exhaust and other applications. Suitable for exhaust gases applications up to 1000 degrees F. Excellent solutions for capturing and exhausting a variety of fumes, dust at source and exhausting to atmosphere.

  • MELT PROOF - all steel construction
  • Built in damper
  • 1000 degree Flameproof triple-ply flexible hose
  • Wall bracket
  • "Stay in place" Extractor arm
  • Optional components available such as: Exhaust Fan complete with motor overload, bird screen, backdraft damper, Exhaust duct, wall flashing and extensions hoses and hoods are available.

CONSTRUCTION:
Internal supporting mechanism made of mild steel tubing c/w 3 spring-assisted joints to provide precise counter balancing of the extractor's inner and outer arm. The FLEXI Extraction Arm comes with a black baked-on enamel steel hood w/ optimized airflow & ring handle, and built in damper and with black baked-on enamel wall bracket. ***The P-149 and P-152 fans mount directly to the wall bracket of the arm***


Do you need FIRM pricing with a QUANTITY discount?Money Icon
Scroll down and earn a discount by filling out the "Qty" boxes and completing the form at the bottom of the page

Main System / Part
Part # Description
P-009-HT Flexi-I Extraction Arm: 160mm (6”)Ø – 4m (14’)L.
  • 850 Degrees F.  
  • P-010-HT Flexi-II Extraction Arm: 160mm (6.5”)Ø – 5m (17’)L.
  • 850 Degrees F.  
  • P-145-HT Flexi-ll Extraction Arm: 200mm (8”)Ø – 4m (14’)L.
  • 850 Degrees F  

  • Main System - Flexi-I Extraction Arms - 6.5'' diameter
    Part # Description
    P-008-HT Flexi-I Extraction Arm: 160mm (6.5”)Ø – 3m (10’)L.
  • 850 Degrees F.  

  • Main System - Flexi-II Extraction Arms - 8'' diameter
    Part # Description
    P-143 Flexi-II Extraction Arm: 200mm (8”)Ø – 2m (7')L. c/w damper and wall/Fan bracket.  

    H-Max Articulating Extension Boom for Flexi-I - 850° F
    Part # Description
    H-MAX-F-1/D-2M-850 2m (7') H-MAX Boom Kit for FLEXI-I Extraction Arms c/w duct kit. 300º F 
    H-MAX-F-2/D-3M-850 3m (10') H-MAX Boom Kit for FLEXI-I Extraction Arms c/w duct kit. 300º F 
    H-MAX-F-3/D-4M-850 4m (14') H-MAX Boom Kit for FLEXI-I Extraction Arms c/w duct kit. 850º F 

    H-Max Articulating Extension Boom for Flexi-II - 850° F
    Part # Description
    H-MAX-FII-1/D-2M-850 2m (7') H-MAX Boom Kit for FLEXI-II Extraction Arms c/w 850º F Hose 
    H-MAX-FII-2/D-3M-850 3m (10') H-MAX Boom Kit for FLEXI-II Extraction Arms c/w 850º F hose. 
    H-MAX-FII-3/D-4M-850 4m (14') H-MAX Boom Kit for FLEXI-II Extraction Arms c/w 850º F hose. 

    Direct Mount Fans - 1.0 HP - (Motor Starter not included)
    Part # Description
    P-149-2 P-Max© direct drive fan 1 HP 208-230V/460V/3/60... 100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"  
    P-149-3 P-Max© direct drive fan 1 HP 575-600V/3/60...100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"  

    Direct Mount Fans - 1.5 HP - (Motor Starter not included)
    Part # Description
    P-154-1.5HP-1 P-Max© direct drive fan 1.5 HP 115-230V/1/60 Note: Must not be used below 8" SP 100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"  

    Direct Mount Fans - 2.0 HP - (Motor Starter not included)
    Part # Description
    P-153-1 2.0 HP direct drive fan 208/1/60 with BI self cleaning aluminum wheel, AMCA type B spark resistance (1200CFM@5 wg), 30 Amp service/breaker (time delay) required
  • If direct mounting to a Hose reel, Ext. arm, Brackets P-045, P-151, or wall flex you need Flange P-153-FL
  • wire required is grade size #10 Minimum

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge" 

  • P-153-2 2 HP direct drive fan 208-230/460/3/60 with BI (cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1200CFM@5 w.g.)
  • If direct mounting this fan to a Hose reel, Extractor arm, Brackets P-045, P-151, or wall flex you will need to order an additional flange Part Number P-153-FL

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge" 

  • P-153-3 2 HP direct drive fan 575/3/60 with BI (cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1200CFM@5 w.g.)
  • If direct mounting this fan to a Hose reel, Extractor arm, Brackets P-045, P-151, or wall flex you will need to order an additional flange Part Number P-153-FL

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"  


  • Direct Mount Fans - 3.0 HP - (Motor Starter not included)
    Part # Description
    P-152-2 3 HP direct drive fan 208-230/460/3/60 with BI (cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1800CFM@5.5 w.g.)
  • If direct mounting this fan to a Hose reel, Extractor arm, Brackets P-045, P-151, or wall flex you will need to order an additional flange Part Number P-153-FL

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge" 

  • P-154-2 3 HP direct drive fan 575/3/60 with BI(cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1800CFM@5.5 w.g.)

  • If direct mounting this fan to a Hose reel, Extractor arm, Brackets P-045, P-151, or wall flex you will need to order an additional flange Part Number P-153-FL

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge  


  • Direct Mount Fans - 5.0 HP - (Motor Starter not included)
    Part # Description
    P-155-1 5 HP direct drive fan 208-230/460/3/60 with BI(cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1300CFM@10 w.g.) Comes complete with an 8" dia. inlet and outlet collar. If a mounting bracket is required pls use part number P-766/155/156/156HF.

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge" 

    P-155-2 5 HP direct drive fan 575/3/60 with BI (cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1300CFM@10 w.g.) Comes complete with an 8" dia. inlet and outlet collar. If a mounting bracket is required pls use part number P-766-155/156/156HF.

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge" 


    Direct Mount Fans - 7.5 HP - (Motor Starter not included)
    Part # Description
    P-156-1 7.5 HP direct drive fan 208-230/460/3/60 with BI(cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1600CFM@10 w.g.) Comes complete with an 8" dia. inlet and outlet collar. If a mounting bracket is required pls use part number P-766-155/156/156HF.

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge" 

    P-156-2 7.5 HP direct drive fan 575/3/60 with BI (cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1600CFM@10 w.g.) Comes complete with an 8" dia. inlet and outlet collar. If a mounting bracket is required pls use part number P-766-155/156/156HF.

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge" 


    Direct Mount Fans - 10 HP - (Motor Starter not included)
    Part # Description
    P-156-HF-1 10 HP direct drive fan 208-230/460/3/60 with BI(cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1600CFM@10 w.g.) Comes complete with an 8" dia. inlet and outlet collar. If a mounting bracket is required pls use part number P-766-155/156/156HF. 
    P-156-HF-2 10 HP direct drive fan 575/3/60 with BI(cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1600CFM@10 w.g.) Comes complete with an 8" dia. inlet and outlet collar. If a mounting bracket is required pls use part number P-766-155/156/156HF. 

    Hose Guard - For High Sparking applications such as Plasma Cutting
    Part # Description
    HS-2500-160 2500 °F Hose Shield for all 6" & 6.5"Ø hoses. 30" in length 
    HS-2500-200 2500 °F Hose Shield for all 8"Ø hoses. 30" in length 

    Variable Frequency Drives
    Part # Description
    VFD-KIT-1HP-115-230-3 1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 1 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD 
  • VFD-KIT-3HP-220-230-3 3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD 

  • Hi Temp hose req'd when Flexi's are to be used in Vehicle Exhaust applications
    Part # Description
    P-146-HT 8"(200mm), 850F hose version of P-146 5m(17'). (Standard hose is removed and replaced with Black Pyroflex hose 850 degrees F)  

    Hose with temp range up to 850°F (455°C)
    Part # Description
    PYRO-12-850 12Ø, 2ply hose 850 deg F - Suitable for use in constant flexing applications or with hose reels (per foot), color BLACK .
  • Minimum length 25' Max length 50' 

  • Stanchions & Wall Brackets
    Part # Description
    P-023 Ceiling/floor stanchion 3m (9.75') for Flexi and Pro-Flex Extraction Arms  
    P-021 Ceiling/floor stanchion 1m (3.3') for Flexi and Pro-Flex Extraction Arms 
    P-022 Ceiling/floor stanchion 2m (6.5') for Flexi and Pro-Flex Extraction Arms  
    P-023-HMAX-SING-R2 VIA-STAN®, Heavy duty stanchion for mounting H-MAX boom's. 10' high. 

    Manual Motor Starter
    Part # Description
    P-024-1 115V/1/60 Fan Motor control station up to 1.5 HP. Permits manual start-stop of the fan. Comes complete with motor overload protection on/off 14A control power cord and plug. Overload rating according to the FLA of the motor. Field assembly & installation required.  
    P-024-2 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 0.6-1.0A OVERLOAD---> HP rating: 1/4@230/3/60, 1/2@460/3/60, 1/2@575/3/60  
    P-024-3 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 1-1.6A OVERLOAD ---> HP rating: 1/3@230/3/60. 3/4@460/3/60, 1.0@575/3/60  
    P-024-4 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 1.6-2.5A OVERLOAD ---> HP rating: 1/2@230/3/60, 1.0@460/3/60, 2@575/3/60  
    P-024-5 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 2.5-4A OVERLOAD---> HP rating: 1.0@230/3/60, 2.0@460/3/60, 3.0@575/3/60  
    P-024-6 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 4.0-6.3A OVERLOAD---> HP rating: 0.25@115/1/60, 0.5@230/1/60, 1.5@230/3/60, 3/0@460/3/60, 5.0@575/3/60 Price update Jan 30 2010 TC 
    P-024-7 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 6.0-10A OVERLOAD---> HP rating: 3.0@230/3/60 
    P-024-8 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 10-16A OVERLOAD---> HP rating: 1.0@115/1/60, 2.0@230/1/60, 5.0@230/3/60, 10@460/3/60, 15@575/3/60V  
    P-024-9 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 16-20A OVERLOAD---> HP rating: 1.5@115/1/60  

    Sensors and Switches (when ordering main unit)
    Part # Description
    LS-12 Hood mounted switch for controlling the fan or light.To be used in conjuction with the P-025 Series Control Panel. 

    Fan Mounting Brackets
    Part # Description
    P-766-HD-GALV Heavy duty galvanized fan mounting bracket w/ hardware to connect fan. 
    P-045 P-MAX fan mount bracket c/w swivel.For P-Max fan on H-Max Ext.Boom for Flexi-I,Pro-Flex Extr.Crane(4,5,6.5),VE Ext.Boom for HoseReels&Hose Drops &VE articulating Crane for HoseDrops (4,5,6)
  • For use only with P-147,P-148, P-149 and P-152 up to P-156 Fans  
  • P-151 P-MAX fan mounting bracket c/w swivel. To be used to install a P-Max fan on a H-Max Extension Boom for Flexi-II and E-Z Arm, Pro-Flex Extraction Crane (8" dia.), VE Extension Boom for Hose Reels&Hose Drops (8" dia.) and VE articulating Crane for Hose Drops (8" dia.)
  • For use only with P-147,P-148, P-149, P-152 up to P-156 Fans  

  • Installation Accessories
    Part # Description
    PDK-8 Industrial grade duct kit for direct exhausting of P-Max fans - for Wall exhaust c/w the following parts:
  • 2 pcs - 24" - 8" diameter lateral duct -1 pc - 8" diameter long radius elbow -1 pc - 8" exhaust fitting -45 degree weather elbow -backdraft damper -bird screen 16" X 16" exterior wall flashing  
  • PDK-RF-8 Industrial grade duct kit for direct exhausting of P-Max fans - for Ceiling/Roof exhaust. Complete with Gravity Back Draft damper. 

    Spare Part (Call for quantity discount)
    Part # Description
    P-144-10 Spring set for P-144, P-145, P-146 
    P-144-7 Skeleton Arm For P-144 
    P-144-HT Flexi-II Extraction Arm: 200mm (8”)Ø – 3m (10’)L.
  • 850 Degrees F.  

  • Other Applications
    As we understand that our products may need to be re-applied during their life span (+20 years), we have listed below other applications that this product can be used for. Before re-applying any of our solutions, please contact one of our representatives to confirm the suitability of your application.

    Machine Shop - Ceramic
    Municipal Operations Center- DOT Garage - Service Garage-Vehicle Maintenance
    Vehicle Exhaust - Cars & Small Trucks
    Vehicle Exhaust - Heavy Equipment