Model: (10-09) MicroAir Systems MC-3000 Air Cleaner


Ceiling/wall mounted cartridge collector for source or ambient capture.

Ambient or Source Capture of:
• Welding Smoke and Fumes
• Grinding Dust
• Powders
• Other Dry Dusts

Features:
• Revolutionary Roto-Pulse Filter Cleaning Systems
• High Capacity Allows for Multiple Drops Without a Loss In CFM
• Modular Design
• Built-In Silencer Plenum
• Hinged Door for Easy Filter Access
• Motor Starter/Overload Relay Standard
• After Pulse Cleaning Standard


OVERALL DIMENSIONS: 36” H X 42” W X 86” L
WEIGHT: 950 LBS
CABINET: 14 GAUGE WELDED GALVANEALED STEEL WITH EXTERIOR SURFACES GROUND SMOOTH.
FINISH: INDUSTRIAL GRADE TEXTURED BAKED, ENAMEL PAINT INSIDE AND OUT.




001 - Spec Drawings: 002 - Brochures:

Do you need FIRM pricing with a QUANTITY discount?Money Icon
Scroll down and earn a discount by filling out the "Qty" boxes and completing the form at the bottom of the page

Main System / Part
Part # Description
MAS-MC3000-SB Standard Blower Module 

Voltage Options
Part # Description
MAS-MC3000-5HP2 5 HP, 208/230 Volt, Three Phase 
MAS-MC3000-5HP4 5 HP, 460 Volt, Three Phase 
MAS-MC3000-7.5HP2 7 1/2 HP, 208/230 Volt, Three Pase 
MAS-MC3000-7.5HP4 7 1/2 HP, 460 Volt, Three Phase 

Filter Module Options
Part # Description
MAS-MC3000-250 Filter Module with 80/20 Cartridges, 250 SF Media each 
MAS-MC3000-291 Filter Module with 80/20 Cartridges, 291 SF Media each 
MAS-MC3000-NC Filter module with no cartridges 
MAS-MC3000-PS Filter Module with poly spun, Ducks Back Cartridges 

After Filter Module/Magnahelic Gauge Options
Part # Description
MAS-MC3000-AFM After Filter Module 
MAS-MC3000-MGAF Magnahelic Gauge - With After Filter 
MAS-MC3000-MGNAF Magnahelic Gauge - With No After Filter 
MAS-MC3000-NFM No After Filter Module Ordered 

After Filter Options
Part # Description
MAS-MC3000-2REF Two EA. Refillable Modules 
MAS-MC3000-2x95 Two EA. 95% HEPA Filters 
MAS-MC3000-2x95/2xREF Two EA. 95% HEPA Filters/Two EA. Refillable Modules 
MAS-MC3000-2x99.97 Two EA. 99.97% HEPA Filters 
MAS-MC3000-2x99.97/2xREF Two EA. 99.97% HEPA Filters/Two EA. Refillable Modules 
MAS-MC3000-4REF Four EA. Refillable Modules 
MAS-MC3000-4x95 Four EA. 95% HEPA Filters 
MAS-MC3000-4x99.97 Four EA. 99.97% HEPA Filters 

Filter Media Options
Part # Description
MAS-MC3000-CHA2 Charcoal for 2 Refillable Modules (60 LBS.) 
MAS-MC3000-CHA4 Charcoal for 4 Refillable Modules 
MAS-MC3000-MOD Modules 
MAS-MC3000-PUR2 Purasorb for 2 Refillable Modules (94 LBS.) 
MAS-MC3000-PUR4 Purasorb for 4 Refillable Modules 

Inlet Plenum Option
Part # Description
MAS-MC3000-IP Inlet Plenum w/one EA. 16 Diameter Collar 

Dust Collection Options
Part # Description
MAS-MC3000-HOP Hopper with blast gate 
MAS-MC3000-TRA Dust tray 

Motor Pulley Options
Part # Description
MAS-MC3000-PU1000 Pulleys for 5 HP 1000 RPM curve (Use for ambient systems) 
MAS-MC3000-PU1200 Pulleys for 5 HP 1200 RPM curve 
MAS-MC3000-PU1375 Pulleys for 5 HP 1375 RPM curve 
MAS-MC3000-PU1675 Pulleys for 5 HP 1675 RPM curve 
MAS-MC3000-PU1800 Pulleys for 7 1/2 HP, 1800 RPM curve 
MAS-MC3000-PU1950 Pulleys for 7 1/2 HP, 1950 RPM curve 

Start/Stop Switch
Part # Description
MAS-MC3000-REM Remote START/STOP switch 

Exhaust Options
Part # Description
MAS-MC3000-SEP Side Exhaust Plenum 

Variable Frequency Drives
Part # Description
VFD-KIT-2HP-115-230-3 2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 2 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD 
  • VFD-KIT-3HP-220-230-3 3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD 

  • Preventative Maintenance Pressure Gauges, etc. (when ordering main unit)
    Part # Description
    LEV-MC-PG-5 Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately. 
    PG-10 Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately. 

    Replacement filters - (Quantity discounts available upon request)
    Part # Description
    MAS-P3032 9.5 X 19.38 X 5.86 95% ASHRAE FILTER  
    PP-24-6 Polyester replacement pad for Pre-filter... 24" X 6" 

    Other Applications
    As we understand that our products may need to be re-applied during their life span (+20 years), we have listed below other applications that this product can be used for. Before re-applying any of our solutions, please contact one of our representatives to confirm the suitability of your application.

    Aerospace - Deburring
    Aerospace - Machining
    Aerospace - Surface Grinders
    Machine Shop - Ceramic
    Machine Shop - CNC
    Machine Shop - Plastics