Model: (05-03) DTH800 - Heavy dusts & smoke - Self cleaning filter system built in - 24''D X 32’’W (800 CFM)*
pre-engineered downdraft table complete with 1 Clean 2® 150 ft2 cartridge filter, integrated fan with TEFC direct drive class II motor and external dust tray generating 800 CFM with 150 FPM downdraft velocity. The DTH-800 draws contaminants away from workers’ breathing zone without hindering movement making these tables an ideal solutions for most welding and light dust/smoke applications.

Do you need FIRM pricing with a QUANTITY discount?Money Icon
Scroll down and earn a discount by filling out the "Qty" boxes and completing the form at the bottom of the page

Main System / Part
Part # Qty Description
DTH-800-1 800 cfm downdraft table, 24 deep x 32 wide work surface at 33 height, 150 fpm downdraft velocity, with 12 tall removable side & back shields and painted steel grate panels. Contains (1) CLEAN-2® cartridge filter (150 sq.ft. of media), manual VIBRA-PULSE ® filter cleaning systems, a 1HP TEFC motor, 115/230/1/60 Hz (12/6 amps), and a removable 5 gallon external dust drawer.71 dBA. AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation. 
DTH-800-2 800 cfm downdraft table, 24 deep x 32 wide work surface at 33 height, 150 fpm downdraft velocity, with 12 tall removable side & back shields and painted steel grate panels. Contains (1) CLEAN-2® cartridge filter (150 sq.ft. of media), manual VIBRA-PULSE ® filter cleaning systems, a 1HP TEFC motor, 230/460/3/60 Hz (12/6 amps), and a removable 5 gallon external dust drawer.71 dBA. AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation. 
DTH-800-3 800 cfm downdraft table, 24 deep x 32 wide work surface at 33 height, 150 fpm downdraft velocity, with 12 tall removable side & back shields and painted steel grate panels. Contains (1) CLEAN-2® cartridge filter (150 sq.ft. of media), manual VIBRA-PULSE ® filter cleaning systems, a 1HP TEFC motor, 575/3/60 Hz (12/6 amps), and a removable 5 gallon external dust drawer.71 dBA. AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation. 

Fan / Motor Upgrades or Options (when ordering main unit)
Part # Qty Description
DTH-800-HP-1.5 1.5 Hp TEFC motor, 115/208-230/1/60 Hz, high pressure, spark resistant, backward incline blower. 900 cfm. 150 fpm downdraft velocity.(15/7.9-7.5 amps). 74 dBA. 
DTH-800-HP-3 1.5 Hp TEFC motor, 208-230/460/575/3/60 Hz, high pressure, spark resistant, backward incline blower. 900 cfm. 170 fpm downdraft velocity. (4.9-4.6/2.3 amps). 

Filter Options (when ordering with main unit)
Part # Qty Description
DTH-800-EXAD External adsorber module. 18 lbs. capacity; 550/650 cfm. Order charcoal separately. (Adds 4 to overall depth and 10 lbs. to ship weight). 
DTH-800-EXDOP External DOP, 95%, 550/650 cfm. (Adds 4 to overall depth and 10 lbs. to ship weight) 
DTH-800-EXHE External HEPA, 99.97%, 550/650 cfm. (Adds 4 to overall depth and 10 lbs. to ship weight) 
DTH-800-EXT HE/AD Kit using EXTERNAL HEPA and EXTERNAL AD options. 
DTH-800-UCP UltraClean Plus Cartridge Filter Option for Standard DTH-800 Unit 

Explosion Proof Option (when ordering main unit)
Part # Qty Description
MOTOR-EXP-1.5-F&G-1PH Single Phase, non-sparking blower wheel & hazardous location (group F & G) motor option. Option comes complete with dust tight conduit connections and terminates in a dust tight enclosure on the exterior of the Collector. Please note that this option should not be used in "Hazardous Location" environments. Please specify voltage when ordering. 
MOTOR-EXP-1.5-F&G-3PH Three Phase, non-sparking blower wheel & hazardous location (group F & G) motor option. Option comes complete with dust tight conduit connections and terminates in a dust tight enclosure on the exterior of the Collector. Please note that this option should not be used in "Hazardous Location" environments. Please specify voltage when ordering. 
GRP-E-1-1-60 Explosion proof motor option 1 HP, 1 Phase, 60Hz (when adding to main unit) 

Hood Options
Part # Qty Description
LEV-TBL-DTL-2 2' Dust-tight Light - 120V/1/60 

Localized Enclosures and Shields
Part # Qty Description
DT-EN-1 Aluminum/Acrylic enclosure c/w top back and side acrylic panels for improved visibility & capture of fumes and dust (3'H X 32"W X 24"D)  

Variable Frequency Drives
Part # Qty Description
VFD-KIT-1HP-115-230-3 1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 1 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD 
  • VFD-KIT-2HP-115-230-3 2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 2 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD 
  • VFD-KIT-3HP-220-230-3 3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD 

  • Sound Attenuation
    Part # Qty Description
    DTH-800-S-EXT External Silencer Option for Standard DTH-800 Unit 

    Fan, Light & Other Electrical Accessories
    Part # Qty Description
    DTH-800-AP-1 Off line AUTO-CLEAN ® cleaning system, 115v only 1 phase. Automatically clean filter when unit is turned off. 230v 1@ price will be same as AP-3. 
    DTH-800-AP-3 Off line AUTO-CLEAN ® cleaning system, 3 phase. Automatically clean filter when unit is turned off. 

    Misc. Options (when ordering main unit)
    Part # Qty Description
    2FR5-1001 Cartridge, AD, refillable with 1 prefilter pad and 1 afterfilter pad. Holds 15 lbs. of charcoal. 
    DCH-1-EXP VENT Explosion Vent door for single and double cartridge collectors. (PCH-1, ALH-1, DCH-1, DTH-1,DS-1 & Mini-Pac. 
    DTH-800-AD Internal AD option: AD cartridge (15 lbs. capacity) with 1 polyester prefilter and afterfilter in place of CLEAN-2 ® cartridge and VIBRA-PULSE ® cleaning system. Order charcoal separately. 
    DTH-800-BF3-LIGHT Enclosure, 36 high, with sides, back and top, plus 40 watt, Dust-Tite, 115 volt work light. Replaces standard 12 tall side & back shields. AS PER CANADIAN LAW; this unit is electrically approved by CSA/ESA field evaluation. 
    DTH-800-FD FIBERDUST cartidge filter in place of lean-2 cartridge 
    DTH-800-MAT Soft Top mat, 12"x12" tiles 
    DTH-800-REG Regulator Gauge Option for Standard DTH-800 Unit 
    DTH-800-ALUM Aluminum grate panels in place of steel grate panels. 24 X 32 
    DTH-800-CASTERS Adds 8 fixed wheels on front, 5 swivel casters on rear, and full width handle. (Adds 3.25 to table height). 
    DTH-800-COATED Vinyl Coated Bar Grate Option for Standard DTH-800 Unit 
    DTH-800-FIBER Fiberglass Bar Grates Option for Standard DTH-800 Unit 
    DTH-800-STEEL Steel grate in place of standard panels. 24 X 32 
    DTH-800-TABLE EXT Table extension, full width with solid surface, 9 deep. 

    Preventative Maintenance Pressure Gauges, etc. (when ordering main unit)
    Part # Qty Description
    DTH-800-PG-5 0-5 mini-helic dial pressure gauge, approximately 5 diameter size. Flush mounted. (not recommended with EXHE, EXAD or EXDOP options) 
    DTH-800-PG-6 0-6 magna-helic pressure gauge, approximately 5 diameter size. Surface mounted. 

    Replacement filters - (Quantity discounts available upon request)
    Part # Qty Description
    1PN6-1749 Aluminum Grate Panels. Price per each (6 required for DTH800) DUSTPAK ALH-1, DUSTPAK ALH-2, DUSTPAK AL-6, DUSTPAK DTH-800, (9 required for DUSTPAK DTH-1700.) 
    2AF2-0011 2" Polyester Frame & Pad 
    2AF9-0001 Adsorber module, flat, refillable. (18" x 24" x 2½"). Holds 18 lbs. of charcoal. 
    2AZ1-0012 1" polyester pad, prefilter for the outside of the AD cartridge. (11½" x 54" x 1"). 
    2AZ1-0013 1" polyester pad, afterfilter for the inside of the Internal AD cartridge. (11½" x 36" x 1"). 
    2AZ2-0013 2 Polyester Filter, pad only 
    7FJ9-5003 95% @ 0.3 microns DOP Filter for PCH/DCH/DTH/ALH units 
    7FJ9-9003 99.97% @ 0.3 microns HEPA Filter for PCH/DCH/DTH/ALH units, Metal Frame  
    7FR0-2021 Cartridge for PCH-1, PCH-2, DCH-1, DCH-2, DC-4, DC-6, DC-8, DC-12, DTH-800, DTH-1700 and DT3000v2.0.
  • Due to the amount of customers not knowing about or using the Vibra-Pulse tubes, these filters will now include The Vibra-Pulse tube. The proper replacement of this Vibra Pulse tube greatly increases filter life and helps maintain flowrate thus resulting in increase worker protection from harmfull fumes 
  • 7FR0-2027 Teflon Filter for DCH/PCH/DTH, TC-4, HC-4, DC-4/6/8/12/18 & DT-3000V2 filter units.
  • VIBRA-PULSE tubes included 
  • 7FR0-5020 OEM Cartridge Filter ALH-1/2/6 filter used in explosive and flamable applications such as aluminum dust applications.  
    CS-350-999 CLEAR SKY SERIES Nano Fiber Filters. Flame Retardant with nano fiber technology. Replacement Filter for DCH/PCH/DTH, TC-4, HC-4, DC-4/6/8/12/18 & DT-3000V2 filter units.
  • Complete with Vibra Pulse Tube  
  • 7FR0-2020 Flame Retardant Cartridge Filter made of 80/20% Cell/Poly Blend,. Replacement Filter for DCH/PCH/DTH, TC-4, HC-4, DC-4/6/8/12/18 & DT-3000V2 filter units.
  • Complete with Vibra Pulse Tube  
  • 7FR0-2020-OEM Replacement Filter  
    7FR0-2029 Cartridge filter, Spunbond, Spark-resistant. Replacement Filter for DCH/PCH/DTH, TC-4, HC-4, DC-4/6/8/12/18 & DT-3000V2 filter units. 
    7FJ9-9003-W 99.97% @ 0.3 microns HEPA Filter for PCH/DCH/DTH/ALH units WOOD FRAME 
    Charcoal-15 15 lbs. Bag of non-recycled coconut shell-based activated carbon.  
    Charcoal-20 20 lbs. of non-recycled coconut shell-based activated charcoal 
    Charcoal-CP40 40" lb of CP Blend of chemisorbant and activated carbon blend.

  • Target Contaminants:
  • Hydrocarbons
  • VOC's
  • Oxides of sulfur
  • Formaldehyde
  • Nitric Oxide
  • Hydrogen Sulfide
  • Lower molecular weight aldehydes and organic acids 


  • Contact Name
    Project
    e-mail
    Company
    Postal Code
    Telephone
    Application/Notes

    If available, please email me...
    a specification drawing of this product.
    a brochure of this product.
    a case study of this product.
    a video of this product.
    a sample system layout of this product.
    a written specification of this product.
    an owner's manual for this product.

    Please have a sales representative call me!