Model: (08-03) Panel Booth - Light dust & Volatile Organic Compounds - Booth sizes to suit & flow to suit
The DUSTRON PANEL BOOTH is the first dust booth to implement the innovative regain of air principle, increasing worker comfort and visibility in the critical work areas.

Capitalizing on the multiplied ventilation effect of "pushing" clean air out across the front of the booth as the blower "pulls" contaminated air into the filters, the Dustron provides velocities of 400/800 FPM at the center zone of the booth where the dust is being generated.

With the fully adjustable Push/Pull Regain Air, the Dustron enhances the conditions and productivity of operations within the booth.


Powerful Performance

Every feature of the dust collection section of the Dustron PANEL BOOTH system is designed for efficiency:

  • High Capture Velocity: Fully adjustable Regain Air for working area velocities of 400+ FPM.

  • High Performance Blowers: Low speed, high flow blowers have airfoil blades for high fan efficiency as well as low noise.

  • Efficient Filtration: Panel filters that are available in the highest degrees of efficiency for both particulate and gas phase contaminants


  • Noise Control

    The Dustron has built-in sound absorption benefiting the workers inside as well as outside the booth:

  • Solid Construction. Standard booth built with 18 gauge steel walls and ceiling.

  • Advanced Core Insulation. Sound-absorbing mats of two-inch fiberglass compressed to one inch.

  • Outer Layer. Further enhancement of sound attenuation with 5 mil aluminized vinyl-impregnated fiberglass cloth covering of mat.


  • Enhanced Work Environment

    The Dustron is designed to provide optimal conditions for large industrial operations where dust and/or noise are a problem.

  • Freedom of Movement. The capture velocity provided throughout the booth means that workers are not "tied" to a limited surface space, source capture arm, or vacuum hose.

  • Visibility. The Dustron's effective source capture of smoke, fumes, and dust provides consistent visibility in the work areas of the booth. In addition the Dustron is well-lit with sealed and gasketed dust-tight fluorescent lights.

  • Safety/Productivity. Many dust booths provide containment without achieving effective environmental control within the booth. The Dustron is designed to effectively capture contaminants for the comfort and health of the booth workers.


  • Multiple Applications

    The Dustron Panel Booth has been built around the variables that go into dealing with a variety of airborne contaminants and applications. Instead of building booths that are “Application Specific” the Dustron Panel booth has been designed to suit multiple applications by simply installing filters that match the application:

  • Simple Maintenance. Filters are easy to change and in some cases washable.

  • Energy Efficient. By selecting filter with the lowest pressure drop available, substantial energy savings can be achieved.

  • Simple Change-out. As applications change, the filters can be changed accordingly, this allows the booth to be used for different applications during it’s life span.


  • Do you need FIRM pricing with a QUANTITY discount?Money Icon
    Scroll down and earn a discount by filling out the "Qty" boxes and completing the form at the bottom of the page

    Main System / Part
    Part # Qty Description
    DPB-10-20-7.5 10' W x 7.5'H x 8' D , 20 FILTERS, 560 SQ.FT., 7.5 HP BLOWER, RATED 9,000 CFM 
    DPB-12-24-10 12' W x 7.5'H x 8' D , 24 FILTERS, 672 SQ.FT.,10 HP BLOWER, RATED 12,000 CFM 
    DPB-16-32-2X5 16' W x 7.5'H x 8' D, 32 FILTERS, 896 SQ.FT., TWO 5HP BLOWERS, RATED 15,200 CFM 
    DPB-20-40-1x15 20' W x 7.5' H x 8'L, 40 FILTERS, 15 HP BLOWER, RATED 18,000 CFM 
    DPB-20-40-2x7.5 20' W x 7.5' H x 8'L, 40 FILTERS, TWO 7.5 HP BLOWERS, RATED 18,000 CFM 
    DPB2-10-40-15 TWO 10' W 7.5' H ENCLOSURES, 19' TOTAL LENGTH, 40 FILTERS, 1120 SQ.FT., ONE 15 HP BLOWER, RATED 18,000 CFM 
    DPB2-12-48-2X10 TWO 12' W x 7.5' H ENCLOSURES, 19' TOTAL LENGTH, 48 FILTERS, 1344 SQ.FT., TWO 10 HP BLOWERS, RATED 24000 CFM 
    DPB2-16-64-2X10 TWO 16' W x 7.5' H ENCLOSURES, 19' TOTAL LENGTH, 64 FILTERS, 1792 SQ.FT., TWO 10 HP BLOWERS, RATED 24000 CFM 
    DPB2-20-80-2X10 TWO 20' W x 7.5' H ENCLOSURES, 19' TOTAL LENGTH, 80 FILTERS, 2240 SQ.FT., TWO 10 HP BLOWERS, RATED 24000 CFM 
    DPB2-8-32-10 TWO 8' W x 7.5' H ENCLOSURES, 19' TOTAL LENGTH, 32 FILTERS, 896 SQ.FT., ONE 10 HP BLOWER, RATED 12,000 CFM 
    DPB-8-16-5 Dustron Panel Booth 8' W x 8' D x 7.5 H, 16 FILTERS, 448 SQ.FT., 5 HP BLOWER, RATED 7,600 CFM 

    Filter Options (when ordering with main unit)
    Part # Qty Description
    DPB-10-20-7.5-OCAF ODOR CONTROL AFTER FILTER 
    DPB-12-24-10-OCAF ODOR CONTROL AFTER FILTER 
    DPB-16-32-2X5-OCAF ODOR CONTROL AFTER FILTER 
    DPB-20-40-2x7.5/1x15-OCAF ODOR CONTROL AFTER FILTER 
    DPB2-10-40-15-OCAF ODOR CONTROL AFTER FILTER 
    DPB2-12-48-2X10-OCAF ODOR CONTROL AFTER FILTER 
    DPB2-16-64-2X10-OCAF ODOR CONTROL AFTER FILTER 
    DPB2-20-80-2X10-OCAF ODOR CONTROL AFTER FILTER 
    DPB2-8-32-10-OCAF ODOR CONTROL AFTER FILTER 
    DPB-8-16-5-OCAF ODOR CONTROL AFTER FILTER 
    DPB-ALL-PF40 PREFILTERS - 24" X 24" X 4" PLEATED 27 SQ. FT. OF FILTER MEDIA, 40% EFFICIENT, MERV 9 
    DPB-ALL-PF60 PREFILTERS - 24 X 24 X 4 PLEATED-27 SQ. FT. OF FILTER MEDIA, 60% EFFICIENT, MERV 11 
    DPB-ALL-PF95 PRIMARY FILTERS - 24" X 24" X 4" PLEATED-122 SQ. FT. OF FILTER MEDIA, 95 % ASHRAE EFFICIENT, MERV 14 
    DPB-ALL-PF99.97 PRIMARY FILTERS - 24" X 24" X 4" PLEATED-122 SQ. FT. OF FILTER MEDIA, 99.97% DOP EFFICIENT 
    DPB-ALL-PFCI PREFILTER PLASTIC CHEVRON IMPINGER FOR SPARKS OR MIST APPLICATIONS 24" X 24" X 4" 
    DPB-ALL-PFMI PREFILTER METAL IMPINGER ( WASHABLE ) FOR MIST APPLICATIONS 24" X 24" X 2" 

    Variable Frequency Drives
    Part # Qty Description
    VFD-KIT-1HP-115-230-3 1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 1 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD 
  • VFD-KIT-2HP-115-230-3 2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 2 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD 
  • VFD-KIT-3HP-220-230-3 3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD 

  • Misc. Options (when ordering main unit)
    Part # Qty Description
    DPB-10-20-7.5-ADD2 ADD 2' TO HEIGHT 
    DPB-10-20-7.5-ADD4 ADD 4' TO LENGTH ( DEPTH ) 
    DPB-10-20-7.5-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS 
    DPB-10-20-7.5-NPP DEDUCT FOR NO PUSH / PULL 
    DPB-10-20-7.5-NSI DEDUCT FOR NO SOUND INSULATION 
    DPB-10-20-7.5-PSC PAINT SPECIAL COLORS 
    DPB-10-20-7.5-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS 
    DPB-10-20-7.5-SHIP SHIPPING WEIGHT IN POUNDS 
    DPB-10-20-7.5-SRC SLOT IN ROOF FOR CRANE 
    DPB-12-24-10-ADD2 ADD 2' TO HEIGHT 
    DPB-12-24-10-ADD4 ADD 4' TO LENGTH ( DEPTH ) 
    DPB-12-24-10-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS 
    DPB-12-24-10-NPP DEDUCT FOR NO PUSH / PULL 
    DPB-12-24-10-NSI DEDUCT FOR NO SOUND INSULATION 
    DPB-12-24-10-PSC PAINT SPECIAL COLORS 
    DPB-12-24-10-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS 
    DPB-12-24-10-SHIP SHIPPING WEIGHT IN POUNDS 
    DPB-12-24-10-SRC SLOT IN ROOF FOR CRANE 
    DPB-16-32-2X5-ADD2 ADD 2' TO HEIGHT 
    DPB-16-32-2X5-ADD4 ADD 4' TO LENGTH ( DEPTH ) 
    DPB-16-32-2X5-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS 
    DPB-16-32-2x5-NPP DEDUCT FOR NO PUSH / PULL 
    DPB-16-32-2x5-NSI DEDUCT FOR NO SOUND INSULATION 
    DPB-16-32-2X5-PSC PAINT SPECIAL COLORS 
    DPB-16-32-2X5-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS 
    DPB-16-32-2X5-SHIP SHIPPING WEIGHT IN POUNDS 
    DPB-16-32-2X5-SRC SLOT IN ROOF FOR CRANE 
    DPB-20-40-2x7.5/1x15-ADD2 ADD 2' TO HEIGHT 
    DPB-20-40-2x7.5/1x15-ADD4 ADD 4' TO LENGTH ( DEPTH ) 
    DPB-20-40-2x7.5/1x15-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS 
    DPB-20-40-2x7.5/1x15-NPP DEDUCT FOR NO PUSH / PULL 
    DPB-20-40-2x7.5/1x15-NSI DEDUCT FOR NO SOUND INSULATION 
    DPB-20-40-2x7.5/1x15-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS 
    DPB-20-40-2x7.5/1x15-SCP SPECIAL COLOR PAINT 
    DPB-20-40-2x7.5/1x15-SHIP SHIPPING WEIGHT IN POUNDS 
    DPB-20-40-2x7.5/1x15-SRC SLOT IN ROOF FOR CRANE 
    DPB2-10-40-15-ADD2 ADD 2' TO HEIGHT 
    DPB2-10-40-15-ADD4 ADD 4' TO LENGTH ( DEPTH ) 
    DPB2-10-40-15-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS 
    DPB2-10-40-15-NPP DEDUCT FOR NO PUSH / PULL 
    DPB2-10-40-15-NSI DEDUCT FOR NO SOUND INSULATION 
    DPB2-10-40-15-PSC PAINT SPECIAL COLORS 
    DPB2-10-40-15-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS 
    DPB2-10-40-15-SHIP SHIPPING WEIGHT IN POUNDS 
    DPB2-10-40-15-SRC SLOT IN ROOF FOR CRANE 
    DPB2-12-48-2X10-ADD2 ADD 2' TO HEIGHT 
    DPB2-12-48-2X10-ADD4 ADD 4' TO LENGTH ( DEPTH ) 
    DPB2-12-48-2X10-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS 
    DPB2-12-48-2x10-NPP DEDUCT FOR NO PUSH / PULL 
    DPB2-12-48-2x10-NSI DEDUCT FOR NO SOUND INSULATION 
    DPB2-12-48-2X10-PSC PAINT SPECIAL COLORS 
    DPB2-12-48-2X10-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS 
    DPB2-12-48-2X10-SHIP SHIPPING WEIGHT IN POUNDS 
    DPB2-12-48-2X10-SRC SLOT IN ROOF FOR CRANE 
    DPB2-16-64-2X10-ADD2 ADD 2' TO HEIGHT 
    DPB2-16-64-2X10-ADD4 ADD 4' TO LENGTH ( DEPTH ) 
    DPB2-16-64-2X10-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS 
    DPB2-16-64-2x10-NPP DEDUCT FOR NO PUSH / PULL 
    DPB2-16-64-2x10-NSI DEDUCT FOR NO SOUND INSULATION 
    DPB2-16-64-2X10-PSC PAINT SPECIAL COLORS 
    DPB2-16-64-2X10-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS 
    DPB2-16-64-2X10-SHIP SHIPPING WEIGHT IN POUNDS 
    DPB2-16-64-2X10-SRC SLOT IN ROOF FOR CRANE 
    DPB2-20-80-2X10-ADD2 ADD 2' TO HEIGHT 
    DPB2-20-80-2X10-ADD4 ADD 4' TO LENGTH ( DEPTH ) 
    DPB2-20-80-2X10-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS 
    DPB2-20-80-2x10-NPP DEDUCT FOR NO PUSH / PULL 
    DPB2-20-80-2x10-NSI DEDUCT FOR NO SOUND INSULATION 
    DPB2-20-80-2X10-PSC PAINT SPECIAL COLORS 
    DPB2-20-80-2X10-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS 
    DPB2-20-80-2X10-SHIP SHIPPING WEIGHT IN POUNDS 
    DPB2-20-80-2X10-SRC SLOT IN ROOF FOR CRANE 
    DPB2-8-32-10-ADD2 ADD 2' TO HEIGHT 
    DPB2-8-32-10-ADD4 ADD 4' TO LENGTH ( DEPTH ) 
    DPB2-8-32-10-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS 
    DPB2-8-32-10-NPP DEDUCT FOR NO PUSH / PULL 
    DPB2-8-32-10-NSI DEDUCT FOR NO SOUND INSULATION 
    DPB2-8-32-10-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS 
    DPB2-8-32-10-SCP SPECIAL COLORS PAINT 
    DPB2-8-32-10-SHIP SHIPPING WEIGHT IN POUNDS 
    DPB2-8-32-10-SRC SLOT IN ROOF FOR CRANE 
    DPB-8-16-5-ADD2 ADD 2' TO HEIGHT 
    DPB-8-16-5-ADD4 ADD 4' TO LENGTH ( DEPTH ) 
    DPB-8-16-5-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS 
    DPB-8-16-5-NPP DEDUCT FOR NO PUSH-PULL 
    DPB-8-16-5-NSI DEDUCT FOR NO SOUND INSULATION 
    DPB-8-16-5-PSC PAINT SPECIAL COLORS 
    DPB-8-16-5-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS 
    DPB-8-16-5-SHIP SHIPPING WEIGHT IN POUNDS 
    DPB-8-16-5-SRC SLOT IN ROOF FOR CRANE 
    DPB-ALL-208/230-3PH VOLTAGE=208 / 230 VOLT 3 PHASE OPTION 
    DPB-ALL-FD FUSED DISCONNECT 
    DPB-ALL-HTCO FIRE PROTECTION - HIGH TEMPERATURE CUT OFF SWITCH 
    DPB-ALL-LU LIGHTING- UPGRADE TO CLASS 1 @ 2 DIV 2 
    DPB-ALL-SCONN SPRINKLER CONNECTION 

    Preventative Maintenance Pressure Gauges, etc. (when ordering main unit)
    Part # Qty Description
    LEV-MC-PG-5 Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately. 
    PG-10 Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately. 

    Replacement filters - (Quantity discounts available upon request)
    Part # Qty Description
    Charcoal-CP40 40" lb of CP Blend of chemisorbant and activated carbon blend.

  • Target Contaminants:
  • Hydrocarbons
  • VOC's
  • Oxides of sulfur
  • Formaldehyde
  • Nitric Oxide
  • Hydrogen Sulfide
  • Lower molecular weight aldehydes and organic acids 


  • Contact Name
    Project
    e-mail
    Company
    Postal Code
    Telephone
    Application/Notes

    If available, please email me...
    a specification drawing of this product.
    a brochure of this product.
    a case study of this product.
    a video of this product.
    a sample system layout of this product.
    a written specification of this product.
    an owner's manual for this product.

    Please have a sales representative call me!