Model: Discontinued (15-05) Hazvent Extraction systems
If your firehouse requires a pneumatic system to extract diesel exhaust fumes, the HazVent system can meet your needs. This exhaust removal system has the same basic components as other pneumatic systems, but, it also has two very distinct features that other systems do not:

Ambient Air Intake

Unlike older designs of pneumatic systems, HazVent offers an optional patented feature to allow ambient air intake. Without this feature, an airtight pneumatic nozzle can create backpressure on the vehicle's engine. This could cause spinning of a non-lubricated turbocharger and produce bearing damage

Two Air Release Valves

HazVent is the only pneumatic system that has two air valve release locations. With most pneumatic systems, when the air pressure is released, it escapes through the MFD valve located mid-point on the hose. The HazVent system enables air to escape from both the nozzle and the MFD valve, allowing the nozzle disconnect to be faster and more reliable.

Do you need FIRM pricing with a QUANTITY discount?Money Icon
Scroll down and earn a discount by filling out the "Qty" boxes and completing the form at the bottom of the page

Main System / Part
Part # Qty Description
CAC-SSRP-401 40 ft.Straight suction Rail complete with 1-Crab and pneumatic connector  
CAC-SSRP-501 50 ft.Straight suction Rail complete with 1-Crab and pneumatic connector  
CAC-SSRP-701 70 ft.Straight suction Rail complete with 1-Crab and pneumatic connector  

Direct Mount Fans - 1.0 HP - (Motor Starter not included)
Part # Qty Description
P-149-2 P-Max© direct drive fan 1 HP 208-230V/460V/3/60... 100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"  
P-149-3 P-Max© direct drive fan 1 HP 575-600V/3/60...100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"  

Direct Mount Fans - 1.5 HP - (Motor Starter not included)
Part # Qty Description
LD-120-2 1300 CFM @ 9 w.g. to 2000 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class II c/w, 3 HP, 230-460V/3/60, 3600 RPM.  
LD-120-3 1300 CFM @ 9 w.g. to 2000 CFM @ 5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class II c/w 3 HP 575V/3/60, 3600 RPM.  
LD-130-2 2000 CFM@10 w.g. to 3000 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class II c/w, 5 HP, 230-460V/3/60, 3600 RPM.  
LD-130-3 2000 CFM@10 w.g. to 3000 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class II c/w, 5 HP, 575-600V/3/60, 3600 RPM.  
LD-150-2 3000 CFM@9 w.g. to 4500 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class II c/w 7.5 HP, 230-460V/3/60, 3600 RPM.  
LD-150-3 3000 CFM@9 w.g. to 4500 CFM@5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class II c/w 7.5 HP, 575V/3/60, 3600 RPM.  
LD-160-2 4000 CFM@10 w.g. to 5000 CFM@6 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 10 HP/3 PH, 230-460V/3/60, 3600 RPM.  
LD-160-3 4000 CFM@10" w.g. to 5000 CFM@6 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 10 HP/3 PH, 230-460-575-600V/3/60, 3600 RPM.  
LD-180-1 5000 CFM@12" w.g. to 7000 CFM@4 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 15 HP/3 HP, 230-460V/3/60, 3600 RPM.  
LD-180-2 5000 CFM@12w.g. to 7000 CFM@4 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 15 HP/3 HP, 575V/3/60, 3600 RPM.  
LD-180-3 8000 CFM@9 w.g. to 9,500 CFM@6 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 20 HP/ 3 HP, 230-460V/3/60, 3600 RPM.  
LD-180-4 8000 CFM@9 w.g. to 9,500 CFM@6 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 20 HP/3 PH, 575/3/60, 3600 RPM.  
LD-240-2 10,000 CFM@7.5" w.g. to 12,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 20 HP/3 HP, 230-460V/3/60, 1750 RPM. 
LD-240-3 10,000 CFM@7.5 w.g. to 12,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 20 HP, 575/3/60, 1750 RPM. 
LD-270-2 12,000 CFM@8" w.g. to 14,500 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 25 HP/3 HP, 230/460/3/60, 1750 RPM. 
LD-270-3 12,000 CFM@8" w.g. to 14,500 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 25 HP/ 3 HP, 575V/3/60, 1750 RPM. 
LD-271-2 14,000 CFM@8 w.g. to 17,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 30 HP 230/460/3/60, 1750 RPM. 
LD-271-3 14,000 CFM@8 w.g. to 17,000 CFM@5.5 w.g. BI Direct Drive Fan c/w slip fit inlet, flanged outlet; Class IV c/w 30 HP 575V/3/60, 1750 RPM. 
P-152-2 3 HP direct drive fan 208-230/460/3/60 with BI (cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1800CFM@5.5 w.g.)
  • If direct mounting this fan to a Hose reel, Extractor arm, Brackets P-045, P-151, or wall flex you will need to order an additional flange Part Number P-153-FL

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge" 

  • P-153-1 2.0 HP direct drive fan 208/1/60 with BI self cleaning aluminum wheel, AMCA type B spark resistance (1200CFM@5 wg), 30 Amp service/breaker (time delay) required
  • If direct mounting to a Hose reel, Ext. arm, Brackets P-045, P-151, or wall flex you need Flange P-153-FL
  • wire required is grade size #10 Minimum

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge" 

  • P-153-2 2 HP direct drive fan 208-230/460/3/60 with BI (cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1200CFM@5 w.g.)
  • If direct mounting this fan to a Hose reel, Extractor arm, Brackets P-045, P-151, or wall flex you will need to order an additional flange Part Number P-153-FL

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge" 

  • P-153-3 2 HP direct drive fan 575/3/60 with BI (cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1200CFM@5 w.g.)
  • If direct mounting this fan to a Hose reel, Extractor arm, Brackets P-045, P-151, or wall flex you will need to order an additional flange Part Number P-153-FL

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"  

  • P-154-1.5HP-1 P-Max© direct drive fan 1.5 HP 115-230V/1/60 Note: Must not be used below 8" SP 100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"  
    P-154-2 3 HP direct drive fan 575/3/60 with BI(cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1800CFM@5.5 w.g.)

  • If direct mounting this fan to a Hose reel, Extractor arm, Brackets P-045, P-151, or wall flex you will need to order an additional flange Part Number P-153-FL

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge  


  • Fan Control Panels (when ordering main unit)
    Part # Qty Description
    CAC-500170-05 Wireless control Panel 1-1 
    CAC-500171-05 Wireless control Panel 1-3 
    CAC-500172-05 Wireless control Panel 1.5 
    CAC-500173-05 Wireless control Panel 1.5-3 
    CAC-500174-05 Wireless control Panel 2-1 
    CAC-500175-05 Wireless control Panel 2-3 
    CAC-500176-05 Wireless control Panel 3-1 
    CAC-500177-05 Wireless control Panel 3-3 
    CAC-500178-05 Wireless control Panel 5-1 
    CAC-500179-05 Wireless control Panel 5-3 
    CAC-500180-05 Wireless control Panel 7.5-1 
    CAC-500181-05 Wireless control Panel 7.5-3 
    CAC-500182-05 Wireless control Panel 10-1 
    CAC-500183-05 Wireless control Panel 10-3 
    CAC-500184-05 Wireless control Panel 15-3 
    CAC-500185-05 Wireless control Panel 20-3-480v 

    Hose with temp range up to 600°F (315°C)
    Part # Qty Description
    CAC-500095-23 Hose 5 X 23 cw325-2py, blue/white
    400 degrees continuous and 500 degrees intermittent 

    Accessories for direct drive and belt driven fans
    Part # Qty Description
    BI-DRAIN Drain, optional accessory for BI Fans, 1/2" Push in connection. Installed on site, step drill bit included with kit. To be installed at the lowest point on the fan. 
    LD-130-DRAIN Drain, Optional accessorie for LD-130 Fans (LD-130-1 & LD-130-2) 
    LD-150-DRAIN Drain, optional accessory for LD-150-1 & LD-150-2 fans.  
    LD-160-DRAIN Drain, Optional accessorie for LD-160 Fans(LD-160-1 & LD-160-2). 
    LD-180-DRAIN Drain, Optional accessorie for LD-180 Fans(LD-180-1 & LD-180-2, LD-180-3 & LD-180-4) 
    LD-240-DRAIN Drain, Optional accessorie for LD-240 Fans(LD-240-1 & LD-240-2). 
    LD-270-DRAIN Drain, Optional accessorie for LD-270 Fans(LD-270-1, LD-270-2, LD-270-3 LD-270-4). 

    Installation Accessories
    Part # Qty Description
    AIRSYSTEM-COMPLETE Complete Air Compression system for VE 
    CAC-500073-07 Tailpipe assembly 5 c/w quick release 
    CAC-500155-01 suction Rail, Plenum 6 
    CAC-500155-02 suction Rail, Plenum 7 
    CAC-500155-03 suction Rail, Plenum 8 
    CAC-500155-09 suction Rail, Plenum 9 


    Contact Name
    Project
    e-mail
    Company
    Postal Code
    Telephone
    Application/Notes

    If available, please email me...
    a specification drawing of this product.
    a brochure of this product.
    a case study of this product.
    a video of this product.
    a sample system layout of this product.
    a written specification of this product.
    an owner's manual for this product.

    Please have a sales representative call me!