model_icon
(14-02) Vehicle Exhaust (Car, truck, motorcycle, Heavy equip.) Single Extractor w/ pulley kit - 4''/5”/6”/8” dia. (300/475/700/1,200 CFM)**
Vehicle exhaust single extractor system complete with rope, pulley kit and saddle. Available in both Low Temp. as well as High Temp Hose.

  • Low Temp. Hose: suitable for temps. up to 250º F
  • High Temp. Hose: suitable for temps. up to 600º F The system consists of 6m (20 ft.) of hose, saddle, rope and pulley kit, and hose clamps. System connects to any of the following:
  • Directly to customer supplied duct work
  • Mounting Bracket - OM-092 (Ordered separately)
  • Mounting Bracket & Fan (Ordered separately)
  • Low Temp Hose Drop
    Part # Description
    SER-4-LT 4" VE single exhaust extractor c/w 6m (20 ft.) 250° F hose, saddle, rope and pulley kit.
    SER-5-LT 5 VE single exhaust extractor c/w 6m (20 ft.) 250° F hose, saddle, rope and pulley kit.
    SER-6-LT 6 VE single exhaust extractor c/w 6m (20 ft.) 250° F hose, saddle, rope and pulley kit.
    SER-8-LT 8 VE single exhaust extractor c/w 6m (20 ft.) 250° F hose, saddle, rope and pulley kit.
    High Temp Hose Drop
    Part # Description
    SER-4-HT 4 VE single exhaust extractor c/w 6m (20 ft.) 850 F hose, saddle, rope and pulley kit.
    SER-5-HT 5 VE single exhaust extractor c/w 6m (20 ft.) 850 F hose, saddle, rope and pulley kit.
    SER-6-HT 6 VE single exhaust extractor c/w 6m (20 ft.) 850 F hose, saddle, rope and pulley kit.
    SER-8-HT 8 VE single exhaust extractor c/w 6m (20 ft.) 850 F hose, saddle, rope and pulley kit.
    Direct Mount Fans - 0.5 HP - (Motor Starter not included)
    Part # Description
    P-147-1 P-Max direct drive fan 0.5 HP 115V/1/60 100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"
    P-147-2 P-Max direct drive fan 0.5 HP 208-230V/1/60
    P-147-3 P-Max direct drive fan 0.5 HP 208-230-460V/3/60
    P-147-4 P-Max direct drive fan 0.5 HP 575V/3/60
    Direct Mount Fans - 0.75 HP - (Motor Starter not included)
    Part # Description
    P-148-1 P-Max© direct drive fan 0.75 HP 115-230V/1/60.
    P-148-2 P-Max© direct drive fan 0.75 HP 230-460V/3/60.
    P-148-3 P-Max© direct drive fan 0.75 HP 575V/3/60. 100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"
    Direct Mount Fans - 1.0 HP - (Motor Starter not included)
    Part # Description
    P-149-2 P-Max© direct drive fan 1 HP 208-230V/460V/3/60... 100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"
    P-149-3 P-Max© direct drive fan 1 HP 575-600V/3/60...100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"
    Direct Mount Fans - 1.5 HP - (Motor Starter not included)
    Part # Description
    P-149-4 P-Max© direct drive fan 1.5 HP
    P-152-1 P-Max© direct drive fan 1.5 HP 115V/230V/1/60 (use 2HP motor when the TSP is less than 4 w.g.)p 100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"
    P-152-2 P-Max© direct drive fan 1.5 HP 208-230V/460V/3/60 (use 2HP motor when the TSP is less than 4 w.g.)

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"

    P-152-3 P-Max© direct drive fan 1.5 HP 575-600V/3/60 (use 2HP motor when the TSP is less than 4 w.g.)
  • please specify 1.5 or 2 HP
  • if you need 2HP, please use P-152-3-2HP

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"

  • P-154-1.5HP-1 P-Max© direct drive fan 1.5 HP 115-230V/1/60 Note: Must not be used below 8" SP 100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"
    Direct Mount Fans - 2.0 HP - (Motor Starter not included)
    Part # Description
    P-153-1 2.0 HP direct drive fan 208/1/60 with BI self cleaning aluminum wheel, AMCA type B spark resistance (1200CFM@5 wg), 30 Amp service/breaker (time delay) required
  • If direct mounting to a Hose reel, Ext. arm, Brackets P-045, P-151, or wall flex you need Flange P-153-FL
  • wire required is grade size #10 Minimum

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"

  • P-153-2 2 HP direct drive fan 208-230/460/3/60 with BI (cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1200CFM@5 w.g.)
  • If direct mounting this fan to a Hose reel, Extractor arm, Brackets P-045, P-151, or wall flex you will need to order an additional flange Part Number P-153-FL

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"

  • Hose Clamps - ''Bridge style
    Part # Description
    MD-530-100-100 4 "Ø Bridge Clamp. Clamping range of 100mm-120mm
  • Looking at screw, the threaded section goes to the right.
  • MD-530-125-100 5 Ø Bridge Clamp. Clamping range of 120mm-140mm
  • Looking at screw, the threaded section goes to right.
  • MD-530-150-100 6 Ø Bridge Clamp. Clamping range of 150mm-170mm
  • Looking at screw, the threaded section goes to right.
  • MD-530-200-100 Clamping range of 200mm-220mm
  • Looking at screw, the threaded section goes to right.
  • Variable Frequency Drives
    Part # Description
    VFD-KIT-1HP-115-230-3 1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 1 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • VFD-KIT-2HP-115-230-3 2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 2 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
  • VFD-KIT-3HP-220-230-3 3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • Fan Control Panels (when ordering main unit)
    Part # Description
    P-025-120S-460V-3PH-20HP Energy Saver E- Man© 460V/3/60. Fan Motor control station. Rated up to 20 HP. HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    P-025-24S-120V-1PH-2HP Energy Saver E- Man© 120V/1/60. Fan Motor control station for 2 HP. Permits automatic start-stop of the fan from the extractor arm hood, hose reel or other device with Remote Switch. Remote mounted switches must be ordered separately (EG: LS-12 - Hood mounted Switch, MS-12 Hose reels...). Comes complete with relevant Motor overload. Also includes a 50 VA 24V AC transformer for powering devices such as halogen Lights.
    Under Carriage Rubber Tailpipe Adapters c/w Vice Grip (Suitable for Round or Oval Tailpipes)
    Part # Description
    SRF-8 8 Rubber nozzle with vice grip - 10 opening
    SRF-8/D 8" Rubber nozzle with vice grip and automatic damper - 10" opening
    SRF-4 4" Rubber nozzle with vice grip - 6" opening
    SRF-4/D 4" Rubber nozzle with vice grip, automatic damper, and SAFETY RELEASE in cases where operator forgets to disconnect from the bus - 6" opening
    SRF-5 5" Rubber nozzle with vice grip - 8" opening
    SRF-5/D 5" Rubber nozzle with vice grip and automatic damper - 8" opening
    SRF-6 6" Rubber nozzle with vice grip - 8" opening
    SRF-6/D 6" Rubber nozzle with vice grip, automatic damper, and SAFETY RELEASE in cases where operator forgets to disconnect from the bus - 8" opening
    Over-head Stack adapter - High Temperature Rubber
    Part # Description
    RCA-10 10" Diesel Stack Adapter - 10" opening for exhaust pipes - C/W under-carriage clip
    RCA-12 10" Diesel Stack Adapter - 12" opening for exhaust pipes - C/W under-carriage clip
    RCA-4 10" Diesel Stack Adapter - 4" opening for exhaust pipe
    RCA-8/D 10" Diesel Stack Adapter with maunal damper - 8" opening for exhaust pipe
    RCA-5 10" Diesel Stack Adapter - 5" opening for exhaust pipe
    RCA-6 10" Diesel Stack Adapter - 6" opening for exhaust pipe
    RCA-8 10" Diesel Stack Adapter - 8" opening for exhaust pipe
    Hose, Hood & Nozzle Options
    Part # Description
    RCA-UCC Under Carriage Clip for RCA Nozzle
    P-230 Hose holder for mounting on OM-092 Fan Mounting Bracket or directly to a wall. For max 150mm hose.
    Automatic Motor Starter
    Part # Description
    P-025-24S-230V-1PH-0.5HP Energy Saver E- Man© 230V/1/60. Fan Motor control station for 0.5 HP. Permits automatic start-stop of the fan from the extractor arm hood, hose reel or other device with Remote Switch. Remote mounted switches must be ordered separately (EG: LS-12 - Hood mounted Switch, MS-12 Hose reels...). Comes complete with relevant Motor overload. Also includes a 50 VA 24V AC transformer for powering devices such as halogen Lights.
    P-025-24S-460V-3PH-20HP Energy Saver E- Man© 460V/3/60. Fan Motor control station. Rated up to 20 HP. Permits automatic start-stop of the fan from the extractor arm hood, hose reel or other device with Remote Switch. Remote mounted switches must be ordered separately (EG: LS-12 - Hood mounted Switch, MS-12 Hose reels...). Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______. Also includes a 50 VA 24V AC transformer for powering devices such as halogen Lights.
    P-025-24S-575V-3PH-20HP Energy Saver E- Man© 575V/3/60. Fan Motor control station. Rated up to 20 HP. Permits automatic start-stop of the fan from the extractor arm hood, hose reel or other device with Remote Switch. Remote mounted switches must be ordered separately (EG: LS-12 - Hood mounted Switch, MS-12 Hose reels...). Comes complete with relevant Motor overload. Also includes a 50 VA 24V AC transformer for powering devices such as halogen Lights.
    P-025-120S-120V-1PH-2.0 HP Energy Saver E- Man© 115V/1/60. Fan Motor control station. Rated up to 2 HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    P-025-120S-240V-1PH-3HP Energy Saver E- Man© 240V/1/60. Fan Motor control station. Rated up to 3 HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    P-025-120S-208/230V-3PH-7.5 HP Energy Saver E- Man© 208-230V/3/60. Fan Motor control station. Rated up to 7.5 HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    P-025-120S-575V-3PH-20HP Energy Saver E- Man© 575V/3/60. Fan Motor control station. Rated up to 20 HP. HP. Permits start-stop of the fan / Dustcollector from a Remote Switch/control. Remote mounted switches must be ordered separately but it is best to interlock the fan with the associate process. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______.Also includes a 50 VA 120V AC transformer for powering the dust collectors sequencer.
    P-025-24S-575V-3PH-30HP Energy Saver E- Man© 575V/3/60. Fan Motor control station. Panel Mounted "Hand/Off/Auto" switch and Pilot light. Rated up to 30 HP. Permits automatic start-stop of the fan from the extractor arm hood, hose reel or other device with Remote Switch. Remote mounted switches must be ordered separately #EG: LS-12 - Hood mounted Switch, MS-12 Hose reels...#. Comes complete with relevant Motor overload. Please specify Motor HP when ordering ______. Also includes a 50 VA 24V AC transformer for powering devices such as halogen Lights.
    Accessories
    Part # Description
    Gripple-2-10 Eyelet No 2 10 ft length
    Gripple-2-15 no. 2 gripple with loop, 15 feet long
    Gripple-2-20 no. 2 gripple with loop, 20 feet long
    Gripple-2-5 no. 2 gripple with loop, 5 feet long
    Gripple-3 Stainless Steel No 3 10' Long with loop gripple attachments.
    Gripple-4 Stainless Steel No 4 Straight eyelet 10 ft, gripples
    TP-6-11 6'-11' Telescoping Pole
    Fan Mounting Brackets
    Part # Description
    P-016 P-Max Fan mounting bracket for Pro-Flex & Supermax Extraction Arms. Only used on the P147, P148, P149 and the P152 fans
    P-016-HD P-Max Fan mounting bracket for Pro-Flex & Supermax Extraction Arms. Heavy Duty Version for P-153, P-154, P-155, P-156 and P-157 Fans. Complete with 4 - 3/8 X 1.5 bolts, nuts and Lock Washers
    P-045 P-MAX fan mount bracket c/w swivel.For P-Max fan on H-Max Ext.Boom for Flexi-I,Pro-Flex Extr.Crane(4,5,6.5),VE Ext.Boom for HoseReels&Hose Drops &VE articulating Crane for HoseDrops (4,5,6)
  • For use only with P-147,P-148, P-149 and P-152 up to P-156 Fans
  • P-045-SS Fan mounting bracket for the Super-Flex or the Extractor Crane 160mm (6.5”) diameter.
    P-151 P-MAX fan mounting bracket c/w swivel. To be used to install a P-Max fan on a H-Max Extension Boom for Flexi-II and E-Z Arm, Pro-Flex Extraction Crane (8" dia.), VE Extension Boom for Hose Reels&Hose Drops (8" dia.) and VE articulating Crane for Hose Drops (8" dia.)
  • For use only with P-147,P-148, P-149, P-152 up to P-156 Fans
  • P-766-LW-SS Lightweight stainless steel fan mounting bracket w/ hardware to connect fan.
    OM-092 For H-MAX or P-Max Fan/Duct mounting bracket for 2 x 150mm (6)Ø Hoses c/w 150/160 mm (6/6.33) hose/duct connection. Package contains:
    Installation Accessories
    Part # Description
    P-045-100 P-MAX fan mount bracket c/w swivel.For P-Max fan on H-Max Ext.Boom for Flexi-I,Pro-Flex Extr.Crane(4,5,6.5),VE Ext.Boom for HoseReels&Hose Drops &VE articulating Crane for HoseDrops (4,5,6)

  • Turning inlet Ø100mm
  • IN-NLS-8 8 No-Loss Stack, 20 Gauge Galvanized, 4' overall height*. Complete with Internal Backdraft Damper. * alternate heights available upon request.
    PDK-RF-8 Industrial grade duct kit for direct exhausting of P-Max fans - for Ceiling/Roof exhaust. Complete with Gravity Back Draft damper.