model_icon
(08-03) Panel Booth - Light dust & Volatile Organic Compounds - Booth sizes to suit & flow to suit **
The DUSTRON PANEL BOOTH is the first dust booth to implement the innovative regain of air principle, increasing worker comfort and visibility in the critical work areas.



Capitalizing on the multiplied ventilation effect of "pushing" clean air out across the front of the booth as the blower "pulls" contaminated air into the filters, the Dustron provides velocities of 400/800 FPM at the center zone of the booth where the dust is being generated.



With the fully adjustable Push/Pull Regain Air, the Dustron enhances the conditions and productivity of operations within the booth.




Powerful Performance


Every feature of the dust collection section of the Dustron PANEL BOOTH system is designed for efficiency:



  • High Capture Velocity: Fully adjustable Regain Air for working area velocities of 400+ FPM.


  • High Performance Blowers: Low speed, high flow blowers have airfoil blades for high fan efficiency as well as low noise.


  • Efficient Filtration: Panel filters that are available in the highest degrees of efficiency for both particulate and gas phase contaminants



  • Noise Control


    The Dustron has built-in sound absorption benefiting the workers inside as well as outside the booth:


  • Solid Construction. Standard booth built with 18 gauge steel walls and ceiling.


  • Advanced Core Insulation. Sound-absorbing mats of two-inch fiberglass compressed to one inch.


  • Outer Layer. Further enhancement of sound attenuation with 5 mil aluminized vinyl-impregnated fiberglass cloth covering of mat.



  • Enhanced Work Environment


    The Dustron is designed to provide optimal conditions for large industrial operations where dust and/or noise are a problem.



  • Freedom of Movement. The capture velocity provided throughout the booth means that workers are not "tied" to a limited surface space, source capture arm, or vacuum hose.


  • Visibility. The Dustron's effective source capture of smoke, fumes, and dust provides consistent visibility in the work areas of the booth. In addition the Dustron is well-lit with sealed and gasketed dust-tight fluorescent lights.


  • Safety/Productivity. Many dust booths provide containment without achieving effective environmental control within the booth. The Dustron is designed to effectively capture contaminants for the comfort and health of the booth workers.




  • Multiple Applications


    The Dustron Panel Booth has been built around the variables that go into dealing with a variety of airborne contaminants and applications. Instead of building booths that are “Application Specific” the Dustron Panel booth has been designed to suit multiple applications by simply installing filters that match the application:


  • Simple Maintenance. Filters are easy to change and in some cases washable.


  • Energy Efficient. By selecting filter with the lowest pressure drop available, substantial energy savings can be achieved.


  • Simple Change-out. As applications change, the filters can be changed accordingly, this allows the booth to be used for different applications during it’s life span.

  • Main System / Part
    Part # Description
    DPB-10-20-7.5 10' W x 7.5'H x 8' D , 20 FILTERS, 560 SQ.FT., 7.5 HP BLOWER, RATED 9,000 CFM
    DPB-12-24-10 12' W x 7.5'H x 8' D , 24 FILTERS, 672 SQ.FT.,10 HP BLOWER, RATED 12,000 CFM
    DPB-16-32-2X5 16' W x 7.5'H x 8' D, 32 FILTERS, 896 SQ.FT., TWO 5HP BLOWERS, RATED 15,200 CFM
    DPB-20-40-1x15 20' W x 7.5' H x 8'L, 40 FILTERS, 15 HP BLOWER, RATED 18,000 CFM
    DPB-20-40-2x7.5 20' W x 7.5' H x 8'L, 40 FILTERS, TWO 7.5 HP BLOWERS, RATED 18,000 CFM
    DPB2-10-40-15 TWO 10' W 7.5' H ENCLOSURES, 19' TOTAL LENGTH, 40 FILTERS, 1120 SQ.FT., ONE 15 HP BLOWER, RATED 18,000 CFM
    DPB2-12-48-2X10 TWO 12' W x 7.5' H ENCLOSURES, 19' TOTAL LENGTH, 48 FILTERS, 1344 SQ.FT., TWO 10 HP BLOWERS, RATED 24000 CFM
    DPB2-16-64-2X10 TWO 16' W x 7.5' H ENCLOSURES, 19' TOTAL LENGTH, 64 FILTERS, 1792 SQ.FT., TWO 10 HP BLOWERS, RATED 24000 CFM
    DPB2-20-80-2X10 TWO 20' W x 7.5' H ENCLOSURES, 19' TOTAL LENGTH, 80 FILTERS, 2240 SQ.FT., TWO 10 HP BLOWERS, RATED 24000 CFM
    DPB2-8-32-10 TWO 8' W x 7.5' H ENCLOSURES, 19' TOTAL LENGTH, 32 FILTERS, 896 SQ.FT., ONE 10 HP BLOWER, RATED 12,000 CFM
    DPB-8-16-5 Dustron Panel Booth 8' W x 8' D x 7.5 H, 16 FILTERS, 448 SQ.FT., 5 HP BLOWER, RATED 7,600 CFM
    Filter Options (when ordering with main unit)
    Part # Description
    DPB-10-20-7.5-OCAF ODOR CONTROL AFTER FILTER
    DPB-12-24-10-OCAF ODOR CONTROL AFTER FILTER
    DPB-16-32-2X5-OCAF ODOR CONTROL AFTER FILTER
    DPB-20-40-2x7.5/1x15-OCAF ODOR CONTROL AFTER FILTER
    DPB2-10-40-15-OCAF ODOR CONTROL AFTER FILTER
    DPB2-12-48-2X10-OCAF ODOR CONTROL AFTER FILTER
    DPB2-16-64-2X10-OCAF ODOR CONTROL AFTER FILTER
    DPB2-20-80-2X10-OCAF ODOR CONTROL AFTER FILTER
    DPB2-8-32-10-OCAF ODOR CONTROL AFTER FILTER
    DPB-8-16-5-OCAF ODOR CONTROL AFTER FILTER
    DPB-ALL-PF40 PREFILTERS - 24" X 24" X 4" PLEATED 27 SQ. FT. OF FILTER MEDIA, 40% EFFICIENT, MERV 9
    DPB-ALL-PF60 PREFILTERS - 24 X 24 X 4 PLEATED-27 SQ. FT. OF FILTER MEDIA, 60% EFFICIENT, MERV 11
    DPB-ALL-PF95 PRIMARY FILTERS - 24" X 24" X 4" PLEATED-122 SQ. FT. OF FILTER MEDIA, 95 % ASHRAE EFFICIENT, MERV 14
    DPB-ALL-PF99.97 PRIMARY FILTERS - 24" X 24" X 4" PLEATED-122 SQ. FT. OF FILTER MEDIA, 99.97% DOP EFFICIENT
    DPB-ALL-PFCI PREFILTER PLASTIC CHEVRON IMPINGER FOR SPARKS OR MIST APPLICATIONS 24" X 24" X 4"
    DPB-ALL-PFMI PREFILTER METAL IMPINGER ( WASHABLE ) FOR MIST APPLICATIONS 24" X 24" X 2"
    Variable Frequency Drives
    Part # Description
    VFD-KIT-1HP-115-230-3 1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 1 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • VFD-KIT-2HP-115-230-3 2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 2 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
  • VFD-KIT-3HP-220-230-3 3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • Misc. Options (when ordering main unit)
    Part # Description
    DPB-10-20-7.5-ADD2 ADD 2' TO HEIGHT
    DPB-10-20-7.5-ADD4 ADD 4' TO LENGTH ( DEPTH )
    DPB-10-20-7.5-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS
    DPB-10-20-7.5-NPP DEDUCT FOR NO PUSH / PULL
    DPB-10-20-7.5-NSI DEDUCT FOR NO SOUND INSULATION
    DPB-10-20-7.5-PSC PAINT SPECIAL COLORS
    DPB-10-20-7.5-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS
    DPB-10-20-7.5-SHIP SHIPPING WEIGHT IN POUNDS
    DPB-10-20-7.5-SRC SLOT IN ROOF FOR CRANE
    DPB-12-24-10-ADD2 ADD 2' TO HEIGHT
    DPB-12-24-10-ADD4 ADD 4' TO LENGTH ( DEPTH )
    DPB-12-24-10-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS
    DPB-12-24-10-NPP DEDUCT FOR NO PUSH / PULL
    DPB-12-24-10-NSI DEDUCT FOR NO SOUND INSULATION
    DPB-12-24-10-PSC PAINT SPECIAL COLORS
    DPB-12-24-10-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS
    DPB-12-24-10-SHIP SHIPPING WEIGHT IN POUNDS
    DPB-12-24-10-SRC SLOT IN ROOF FOR CRANE
    DPB-16-32-2X5-ADD2 ADD 2' TO HEIGHT
    DPB-16-32-2X5-ADD4 ADD 4' TO LENGTH ( DEPTH )
    DPB-16-32-2X5-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS
    DPB-16-32-2x5-NPP DEDUCT FOR NO PUSH / PULL
    DPB-16-32-2x5-NSI DEDUCT FOR NO SOUND INSULATION
    DPB-16-32-2X5-PSC PAINT SPECIAL COLORS
    DPB-16-32-2X5-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS
    DPB-16-32-2X5-SHIP SHIPPING WEIGHT IN POUNDS
    DPB-16-32-2X5-SRC SLOT IN ROOF FOR CRANE
    DPB-20-40-2x7.5/1x15-ADD2 ADD 2' TO HEIGHT
    DPB-20-40-2x7.5/1x15-ADD4 ADD 4' TO LENGTH ( DEPTH )
    DPB-20-40-2x7.5/1x15-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS
    DPB-20-40-2x7.5/1x15-NPP DEDUCT FOR NO PUSH / PULL
    DPB-20-40-2x7.5/1x15-NSI DEDUCT FOR NO SOUND INSULATION
    DPB-20-40-2x7.5/1x15-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS
    DPB-20-40-2x7.5/1x15-SCP SPECIAL COLOR PAINT
    DPB-20-40-2x7.5/1x15-SHIP SHIPPING WEIGHT IN POUNDS
    DPB-20-40-2x7.5/1x15-SRC SLOT IN ROOF FOR CRANE
    DPB2-10-40-15-ADD2 ADD 2' TO HEIGHT
    DPB2-10-40-15-ADD4 ADD 4' TO LENGTH ( DEPTH )
    DPB2-10-40-15-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS
    DPB2-10-40-15-NPP DEDUCT FOR NO PUSH / PULL
    DPB2-10-40-15-NSI DEDUCT FOR NO SOUND INSULATION
    DPB2-10-40-15-PSC PAINT SPECIAL COLORS
    DPB2-10-40-15-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS
    DPB2-10-40-15-SHIP SHIPPING WEIGHT IN POUNDS
    DPB2-10-40-15-SRC SLOT IN ROOF FOR CRANE
    DPB2-12-48-2X10-ADD2 ADD 2' TO HEIGHT
    DPB2-12-48-2X10-ADD4 ADD 4' TO LENGTH ( DEPTH )
    DPB2-12-48-2X10-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS
    DPB2-12-48-2x10-NPP DEDUCT FOR NO PUSH / PULL
    DPB2-12-48-2x10-NSI DEDUCT FOR NO SOUND INSULATION
    DPB2-12-48-2X10-PSC PAINT SPECIAL COLORS
    DPB2-12-48-2X10-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS
    DPB2-12-48-2X10-SHIP SHIPPING WEIGHT IN POUNDS
    DPB2-12-48-2X10-SRC SLOT IN ROOF FOR CRANE
    DPB2-16-64-2X10-ADD2 ADD 2' TO HEIGHT
    DPB2-16-64-2X10-ADD4 ADD 4' TO LENGTH ( DEPTH )
    DPB2-16-64-2X10-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS
    DPB2-16-64-2x10-NPP DEDUCT FOR NO PUSH / PULL
    DPB2-16-64-2x10-NSI DEDUCT FOR NO SOUND INSULATION
    DPB2-16-64-2X10-PSC PAINT SPECIAL COLORS
    DPB2-16-64-2X10-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS
    DPB2-16-64-2X10-SHIP SHIPPING WEIGHT IN POUNDS
    DPB2-16-64-2X10-SRC SLOT IN ROOF FOR CRANE
    DPB2-20-80-2X10-ADD2 ADD 2' TO HEIGHT
    DPB2-20-80-2X10-ADD4 ADD 4' TO LENGTH ( DEPTH )
    DPB2-20-80-2X10-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS
    DPB2-20-80-2x10-NPP DEDUCT FOR NO PUSH / PULL
    DPB2-20-80-2x10-NSI DEDUCT FOR NO SOUND INSULATION
    DPB2-20-80-2X10-PSC PAINT SPECIAL COLORS
    DPB2-20-80-2X10-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS
    DPB2-20-80-2X10-SHIP SHIPPING WEIGHT IN POUNDS
    DPB2-20-80-2X10-SRC SLOT IN ROOF FOR CRANE
    DPB2-8-32-10-ADD2 ADD 2' TO HEIGHT
    DPB2-8-32-10-ADD4 ADD 4' TO LENGTH ( DEPTH )
    DPB2-8-32-10-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS
    DPB2-8-32-10-NPP DEDUCT FOR NO PUSH / PULL
    DPB2-8-32-10-NSI DEDUCT FOR NO SOUND INSULATION
    DPB2-8-32-10-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS
    DPB2-8-32-10-SCP SPECIAL COLORS PAINT
    DPB2-8-32-10-SHIP SHIPPING WEIGHT IN POUNDS
    DPB2-8-32-10-SRC SLOT IN ROOF FOR CRANE
    DPB-8-16-5-ADD2 ADD 2' TO HEIGHT
    DPB-8-16-5-ADD4 ADD 4' TO LENGTH ( DEPTH )
    DPB-8-16-5-DCMO DUST COLLECTOR MODULE ONLY WITH CONTROLS
    DPB-8-16-5-NPP DEDUCT FOR NO PUSH-PULL
    DPB-8-16-5-NSI DEDUCT FOR NO SOUND INSULATION
    DPB-8-16-5-PSC PAINT SPECIAL COLORS
    DPB-8-16-5-SAFH SAFETY AFTER FILTER HOUSING (TO GIVE 3 LAYERS OF FILTRATION) MUST ADD FILTERS
    DPB-8-16-5-SHIP SHIPPING WEIGHT IN POUNDS
    DPB-8-16-5-SRC SLOT IN ROOF FOR CRANE
    DPB-ALL-208/230-3PH VOLTAGE=208 / 230 VOLT 3 PHASE OPTION
    DPB-ALL-FD FUSED DISCONNECT
    DPB-ALL-HTCO FIRE PROTECTION - HIGH TEMPERATURE CUT OFF SWITCH
    DPB-ALL-LU LIGHTING- UPGRADE TO CLASS 1 @ 2 DIV 2
    DPB-ALL-SCONN SPRINKLER CONNECTION
    Preventative Maintenance Pressure Gauges, etc. (when ordering main unit)
    Part # Description
    LEV-MC-PG-5 Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately.
    PG-10 Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately.
    Replacement filters - (Quantity discounts available upon request)
    Part # Description
    Charcoal-CP40 40" lb of CP Blend of chemisorbant and activated carbon blend.

  • Target Contaminants:
  • Hydrocarbons
  • VOC's
  • Oxides of sulfur
  • Formaldehyde
  • Nitric Oxide
  • Hydrogen Sulfide
  • Lower molecular weight aldehydes and organic acids
  •  
    Other Industries / Processes
    As we understand that our products may need to be re-applied during their life span (+20 years), we have listed below other applications that this product can be used For. Before re-applying any of our solutions, please contact one of our representatives to confirm the suitability of your application.

    Educational Facilities - Auto Shop
    Educational Facilities - Machine Shop
    Educational Facilities - Welding Shop
    Forensics - Forensics Laboratories
    Painting - Small Paint Booth
    Welding Shops - Stainless Welding
    Welding Shops - Steel Welding
    Welding Shops - Torch Cutting Ventilation
    Woodworking - Chainsaw