model_icon
(10-01) F90 - Dusts, Mists & Gases - Multiple filter configurations available / Washable and/or Disposable filters - With Fan (500-2,000 CFM)* **
500 - 2000 CFM Ducted Industrial Air Cleaner that comes standard with (1) 4” deep 30% pleated pre-filter, (1) 65% bag filter, 96ft² of media, and a 1.5 HP TEFC motor 208-230/460/575/3/60Hz (5/2.5 amps). Unit can be upgraded with different filter and fan packages to suit a variety of applications and contaminants. CONSTRUCTION:

16 Ga. steel cabinet with powder-coat finish; includes Ultra-Seal® filter sealing system, side access door to filters, belt drive, ball bearing 10’ x 10’ blower with adjustable speed motor pulley, 4-way, adjustable airfoil blade, exhaust grille and motor wired to external junction box; unit wired for 208V unless otherwise specified. (Motor starter not included.)
001 - Spec Drawings:002 - Brochures:017 - DWG and RVT models:
Main System / Part
Part # Description
F90 2800 CFM industrial air cleaner with (1) 4” deep 30" pleated prefilter, (1) 65% bag filter (96ft²) and a 1.5 HP TEFC motor, 460/3/60Hz
Voltage Options
Part # Description
VOLT-115-230 To indicate the voltage for the specified unit.
  • 115/208-230/1/60
  • VOLT-230-460/3/60 To indicate the voltage for the specified unit.
  • 208-230-460/3/60
  • Motor starter and power cord not included
  • VOLT-575/3/60 To indicate the voltage for the specified unit.
  • 575/3/60
  • Motor starter and power cord not included
  • Fan / Motor Upgrades or Options (when ordering main unit)
    Part # Description
    F90-1- PHASE 115V Option for Standard F90 Unit1.5 HP TEFC motor, 115/230/1/60Hz (16/8 amps), wired to external junction box, with on-off switch on 115V units.
    F90-3HP 3 HP TEFC motor, 208-230/460/575/3/60Hz, high pressure.3 HP TEFC motor, 208-230/460/575/3/60Hz, high pressure. Class II, spark resistant, direct drive, B.I. blower
    F90-3HP-1PHASE 3 HP TEFC motor, 115/230/1/60Hz, high pressure, Class II, spark resistant, direct drive, B.I. blower.
    Filter Options (when ordering with main unit)
    Part # Description
    F90-0.95 95% bag filter (96 sq.ft) in place of standard 65% bag.
    F90-2A 2 aluminum mesh filter in place of 4 pleated prefilter.
    F90-2P 2 polyester filter with frame, 3.3 sq.ft., in place of 4 pleated prefilter.
    F90-95DOP Incl. 95% DOP proceeded by 95% bag filter (add 40 lbs. to shipping wt.). Rated 1600 CFM. (24" x 20" x 4")
    F90-AD Adsorption option: includes (1) 2 aluminum mesh prefilter, (1) 95% short bag filter (36 sq.ft.), (2) refillable, v-bank absorber modules and (1) 2 pleated after-filter. 40 lbs. capacity; rated 1600 cfm. Order charcoal separately. (Adds 18 lbs. to ship weight)
    F90-CV Chevron Filter Option for Standard F90 Unit
  • This option includes (1) 2" aluminum mesh prefilter, (1) 4" CHEVRON ® mist eliminator, (1) 95% bag filter (96 sq.ft.) and (2) drains in cabinet (3/4" FPT).
  • F90-EC Easy Clean Bag Filter Option for Standard F90 Unit, 24x20x28
    F90-HEPA-12 99.97% DOP HEPA Filter Option for Standard F90 Unit - Larger Filter, ( 24" x 20" x 12")
    F90-HEPA-4 99.97% DOP HEPA Filter Option for Standard F90 Unit, ( 24" x 20" x 4")
    F90-R Reduced maintenance prefilter, includes plenum and 10 sq.ft. polyester pad.(24x20x28)
    Variable Frequency Drives
    Part # Description
    VFD-KIT-1HP-115-230-3 1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 1 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • VFD-KIT-2HP-115-230-3 2HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 2 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120 or 220/1/60 V system with a VFD
  • VFD-KIT-3HP-220-230-3 3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • Fan Control Panels (when ordering main unit)
    Part # Description
    Starter-Mag-F90 Magnetic starter,1.5-3HP, 208-460volt, shipped loose.
    Starter-Man-F90 Manual Starter,1.5- 3HP, 208-460 volt, shipped loose
    Starter-MNT Kit for mounting Magnetic or Manual starters for T-140
    Starter-MNT-F90 Kit for mounting Magnetic or Manual starters
    Sound Attenuation
    Part # Description
    F90-S-EXT Exhaust silencer Option for Standard F90 Unit
    Misc. Options
    Part # Description
    F90-DK Drain kit for F90 unit ( 2 kits needed with Chevron Option)
    Misc. Options (when ordering main unit)
    Part # Description
    2AU4-3004 Reduced maintenance prefilter, includes plenum and 10Sq ft. polyester pad, )Adds 20" to overall legth and 35 lbs to ship weight)
    2KT1-2701 AD or Hepa conversion Part for F120 or F90
    2KT9-3007 Outdoor Option-rain shield to protect upper door gasket
    HP-1.5-F90 1.5 HP TEFC Motor 115/230/1/60Jz (16/8 aamps) wired to external junction box, with on-off switch on 115v units..
    Preventative Maintenance Pressure Gauges, etc. (when ordering main unit)
    Part # Description
    F90-PG-10 0-10 magna-helic pressure gauge, approximately 5 diameter size. Surface mounted.
    LEV-MC-PG-5 Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-5 pressure gauge. 3/16 inside diameter tubing ordered separately.
    PG-10 Pressure Gauge - complete with Wall, Ceiling or table mounting bracket and 0-10 pressure gauge. 3/16 inside diameter tubing ordered separately.
    PG-6 0-6 Magnahelic dial pressure gauge, surface mounted.
    Installation Accessories
    Part # Description
    F90-EB 3/8 Eyebolts Option for Standard F90 Unit
    F90-IA Additional inlet collar, up to 16 dia. (Specify location).
    F90-SP Source capture inlet/outlet plenum, with 14 dia. Collar.
    Replacement filters - (Quantity discounts available upon request)
    Part # Description
    2AF1-8032 Easy Clean Bag Filter for F90 - Dusts, Mists & Gases - Multiple filter configurations available / Washable and/or Disposable filters - With Fan (500-2,000 CFM)
    2AF2-8001 polyester filter with frame for F90 and F91, (24" x 20" x 2")
    2AF2-8101 Louver oil mist separator for PAC-90, (20" x 24" x 2").
    2AF4-8100 Chevron Filter impingement filter 24x20x4 CV
    2AF9-0002 AD Module, Absorber module,v-bank refillable. Holds 18 lbs. of charcoal, AD
    2AZ2-0009 2" Polyester Prefilter 24x24x2
    2AZ2-0014 Polyester Prefilter, for R option only, (26" x 51" x 2"
    7FA8-0201 2 Mesh Prefilter. (24" x 20" x 2")
    7FB6-5201 65% Short Bag Filter, (24" x 20" x 14")
    7FB6-5232 65% Bag Filter,(24" x 20" x3 2")
    7FB6-5232-OEM 65% Bag Filter for F90, F91 and PAC-90., (24" x 20" x 32")
    7FB9-0201 95% Short Bag Filter for F-90 filter systems, L14xW24xH20 8bags
    7FB9-0201-OEM 95% Short Bag Filter for F90, F91 and PAC-90, (24" x 20" x 14").
    7FB9-0226 bag filter for F90 and F91. Minipleat filter., (24" x 20" x 26"L)
    7FB9-0232 95% Bag Filter for PAC-90 and F-90, (24" x 20" x 32")
    7FH9-9212 99.97% DOP HEPA Filter, wood frame, 24x20x12
    7FH9-9212-OEM HEPA, filter for F90, F91 and PAC-90,(24" x 20" x 12")
    7FJ9-5204 DOP, Minipleat filter for F90 and F91, (24" x 20" x 4"
    7FJ9-5212 DOP for F90 and F91, (24" x 20" x 12")
    7FJ9-9204 HEPA, Minipleat filter for F90 and P91, (24" x 20" x 4")
    7FP1-4505-P High Efficiency Filter for Pac-91, MP-30/60/120, F-120/122/240/360/480/, 202, 203, Mistpak Pro 2/3/4, Panel Filter Booth, Dustron Panel Booth, Easy Bench & Air Pod. 24"X24X"4"
    7FP3-0104 4" replacement pre-filter, 30% eff. for EASY BENCH, T-140, F-120, F122, F240, F360, F480, 2400-DRY, 200, 202, 203, 2400VOM, T-3000, Pac-91 and others. (24" x 24" x 4")
    7FP3-0202 pleated filter for F90 and P91, (24" x 20" x 2")
    7FP3-0204 4 Pleated Prefilter 30% Efficiency F90 - Dusts, Mists & Gases - Multiple filter configurations available / Washable and/or Disposable filters - With Fan (500-2,000 CFM), L4 W24 H20
    7FP3-0204-OEM pleated filter for F90, F91 and PAC-90, (24" x 20" x 4").
    Charcoal-20 20 lbs. of non-recycled coconut shell-based activated charcoal
    Charcoal-CP40 40" lb of CP Blend of chemisorbant and activated carbon blend.

  • Target Contaminants:
  • Hydrocarbons
  • VOC's
  • Oxides of sulfur
  • Formaldehyde
  • Nitric Oxide
  • Hydrogen Sulfide
  • Lower molecular weight aldehydes and organic acids
  • PP-24-6 Polyester replacement pad for Pre-filter... 24" X 6"