model_icon
(14-01) Touchless -Vehicle Exhaust Extraction Arms- up to 43 feet long-600 to 1500 CFM**
“Ready to install and use” FLEXI Extraction Arms for vehicle exhaust and other applications. Suitable for exhaust gases applications up to 1000 degrees F. Excellent solutions for capturing and exhausting a variety of fumes, dust at source and exhausting to atmosphere.



  • MELT PROOF - all steel construction

  • Built in damper

  • 1000 degree Flameproof triple-ply flexible hose

  • Wall bracket

  • "Stay in place" Extractor arm

  • Optional components available such as: Exhaust Fan complete with motor overload, bird screen, backdraft damper, Exhaust duct, wall flashing and extensions hoses and hoods are available. CONSTRUCTION:

    Internal supporting mechanism made of mild steel tubing c/w 3 spring-assisted joints to provide precise counter balancing of the extractor's inner and outer arm. The FLEXI Extraction Arm comes with a black baked-on enamel steel hood w/ optimized airflow & ring handle, and built in damper and with black baked-on enamel wall bracket. ***The P-149 and P-152 fans mount directly to the wall bracket of the arm***
Main System / Part
Part # Description
P-009-HT Flexi-I Extraction Arm: 160mm (6”)Ø – 4m (14’)L.
  • 850 Degrees F.
  • P-010-HT Flexi-II Extraction Arm: 160mm (6.5”)Ø – 5m (17’)L.
  • 850 Degrees F.
  • P-145-HT Flexi-ll Extraction Arm: 200mm (8”)Ø – 4m (14’)L.
  • 850 Degrees F
  • Main System - Flexi-I Extraction Arms - 6.5'' diameter
    Part # Description
    P-008-HT Flexi-I Extraction Arm: 160mm (6.5”)Ø – 3m (10’)L.
  • 850 Degrees F.
  • Main System - Flexi-II Extraction Arms - 8'' diameter
    Part # Description
    P-143 Flexi-II Extraction Arm: 200mm (8”)Ø – 2m (7')L. c/w damper and wall/Fan bracket.
    H-Max Articulating Extension Boom for Flexi-I - 850° F
    Part # Description
    H-MAX-F-1/D-2M-850 2m (7') H-MAX Boom Kit for FLEXI-I Extraction Arms c/w duct kit. 300º F
    H-MAX-F-2/D-3M-850 3m (10') H-MAX Boom Kit for FLEXI-I Extraction Arms c/w duct kit. 300º F
    H-MAX-F-3/D-4M-850 4m (14') H-MAX Boom Kit for FLEXI-I Extraction Arms c/w duct kit. 850º F
    H-Max Articulating Extension Boom for Flexi-II - 850° F
    Part # Description
    H-MAX-FII-1/D-2M-850 2m (7') H-MAX Boom Kit for FLEXI-II Extraction Arms c/w 850º F Hose
    H-MAX-FII-2/D-3M-850 3m (10') H-MAX Boom Kit for FLEXI-II Extraction Arms c/w 850º F hose.
    H-MAX-FII-3/D-4M-850 4m (14') H-MAX Boom Kit for FLEXI-II Extraction Arms c/w 850º F hose.
    Direct Mount Fans - 1.0 HP - (Motor Starter not included)
    Part # Description
    P-149-2 P-Max© direct drive fan 1 HP 208-230V/460V/3/60... 100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"
    P-149-3 P-Max© direct drive fan 1 HP 575-600V/3/60...100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"
    Direct Mount Fans - 1.5 HP - (Motor Starter not included)
    Part # Description
    P-152-2 P-Max© direct drive fan 1.5 HP 208-230V/460V/3/60 (use 2HP motor when the TSP is less than 4 w.g.)

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"

    P-154-1.5HP-1 P-Max© direct drive fan 1.5 HP 115-230V/1/60 Note: Must not be used below 8" SP 100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"
    Direct Mount Fans - 2.0 HP - (Motor Starter not included)
    Part # Description
    P-153-1 2.0 HP direct drive fan 208/1/60 with BI self cleaning aluminum wheel, AMCA type B spark resistance (1200CFM@5 wg), 30 Amp service/breaker (time delay) required
  • If direct mounting to a Hose reel, Ext. arm, Brackets P-045, P-151, or wall flex you need Flange P-153-FL
  • wire required is grade size #10 Minimum

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"

  • P-153-2 2 HP direct drive fan 208-230/460/3/60 with BI (cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1200CFM@5 w.g.)
  • If direct mounting this fan to a Hose reel, Extractor arm, Brackets P-045, P-151, or wall flex you will need to order an additional flange Part Number P-153-FL

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"

  • P-153-3 2 HP direct drive fan 575/3/60 with BI (cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1200CFM@5 w.g.)
  • If direct mounting this fan to a Hose reel, Extractor arm, Brackets P-045, P-151, or wall flex you will need to order an additional flange Part Number P-153-FL

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"

  • Direct Mount Fans - 5.0 HP - (Motor Starter not included)
    Part # Description
    P-155-1 5 HP direct drive fan 208-230/460/3/60 with BI(cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1300CFM@10 w.g.) Comes complete with an 8" dia. inlet and outlet collar. If a mounting bracket is required pls use part number P-766/155/156/156HF.

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"

    P-155-2 5 HP direct drive fan 575/3/60 with BI (cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1300CFM@10 w.g.) Comes complete with an 8" dia. inlet and outlet collar. If a mounting bracket is required pls use part number P-766-155/156/156HF.

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"

    Direct Mount Fans - 7.5 HP - (Motor Starter not included)
    Part # Description
    P-156-1 7.5 HP direct drive fan 208-230/460/3/60 with BI(cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1600CFM@10 w.g.) Comes complete with an 8" dia. inlet and outlet collar. If a mounting bracket is required pls use part number P-766-155/156/156HF.

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"

    P-156-2 7.5 HP direct drive fan 575/3/60 with BI (cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1600CFM@10 w.g.) Comes complete with an 8" dia. inlet and outlet collar. If a mounting bracket is required pls use part number P-766-155/156/156HF.

    100% Weather-proof and can me mounted outdoors/rooftop. Fans are able to be rotated at 45deg increments to allow for angular up/down discharge"

    Direct Mount Fans - 10 HP - (Motor Starter not included)
    Part # Description
    P-156-HF-1 10 HP direct drive fan 208-230/460/3/60 with BI(cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1600CFM@10 w.g.) Comes complete with an 8" dia. inlet and outlet collar. If a mounting bracket is required pls use part number P-766-155/156/156HF.
    P-156-HF-2 10 HP direct drive fan 575/3/60 with BI(cast) aluminum wheel with self cleaning blades, AMCA type B spark resistance construction (rated for 1600CFM@10 w.g.) Comes complete with an 8" dia. inlet and outlet collar. If a mounting bracket is required pls use part number P-766-155/156/156HF.
    Hose Guard - For High Sparking applications such as Plasma Cutting
    Part # Description
    HS-2500-160 2500 °F Hose Shield for all 6" & 6.5"Ø hoses. 30" in length
    HS-2500-200 2500 °F Hose Shield for all 8"Ø hoses. 30" in length
    Variable Frequency Drives
    Part # Description
    VFD-KIT-1HP-115-230-3 1HP 120-240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 1 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • VFD-KIT-3HP-220-230-3 3HP 240V Hybrid VFD 1 Phase In, 230V 3 Phase Output 60Hz complete with:

  • VFD NEMA 4
  • 3 HP Motor
  • Wiring
  • Labor
  • Re-certification

  • PLEASE NOTE: this kit is only required when upgrading a 120V system with a VFD
  • Hi Temp hose req'd when Flexi's are to be used in Vehicle Exhaust applications
    Part # Description
    P-146-HT 8"(200mm), 850F hose version of P-146 5m(17'). (Standard hose is removed and replaced with Black Pyroflex hose 850 degrees F)
    Stanchions & Wall Brackets
    Part # Description
    P-023 Ceiling/floor stanchion 3m (9.75') for Flexi and Pro-Flex Extraction Arms
    P-021 Ceiling/floor stanchion 1m (3.3') for Flexi and Pro-Flex Extraction Arms
    P-022 Ceiling/floor stanchion 2m (6.5') for Flexi and Pro-Flex Extraction Arms
    P-023-HMAX-SING-R2 VIA-STAN®, Heavy duty stanchion for mounting H-MAX boom's. 10' high.
    Manual Motor Starter
    Part # Description
    P-024-1 115V/1/60 Fan Motor control station up to 1.5 HP. Permits manual start-stop of the fan. Comes complete with motor overload protection on/off 14A control power cord and plug. Overload rating according to the FLA of the motor. Field assembly & installation required.
    P-024-2 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 0.6-1.0A OVERLOAD---> HP rating: 1/4@230/3/60, 1/2@460/3/60, 1/2@575/3/60
    P-024-3 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 1-1.6A OVERLOAD ---> HP rating: 1/3@230/3/60. 3/4@460/3/60, 1.0@575/3/60
    P-024-4 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 1.6-2.5A OVERLOAD ---> HP rating: 1/2@230/3/60, 1.0@460/3/60, 2@575/3/60
    P-024-5 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 2.5-4A OVERLOAD---> HP rating: 1.0@230/3/60, 2.0@460/3/60, 3.0@575/3/60
    P-024-6 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 4.0-6.3A OVERLOAD---> HP rating: 0.25@115/1/60, 0.5@230/1/60, 1.5@230/3/60, 3/0@460/3/60, 5.0@575/3/60 Price update Jan 30 2010 TC
    P-024-7 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 6.0-10A OVERLOAD---> HP rating: 3.0@230/3/60
    P-024-8 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 10-16A OVERLOAD---> HP rating: 1.0@115/1/60, 2.0@230/1/60, 5.0@230/3/60, 10@460/3/60, 15@575/3/60V
    P-024-9 Fan Motor control station. Permits manual start-stop of the fan. Comes complete with motor overload protection and on/off control. 16-20A OVERLOAD---> HP rating: 1.5@115/1/60
    Sensors and Switches (when ordering main unit)
    Part # Description
    LS-12 Hood mounted switch for controlling the fan or light.To be used in conjuction with the P-025 Series Control Panel.
    Fan Mounting Brackets
    Part # Description
    P-045 P-MAX fan mount bracket c/w swivel.For P-Max fan on H-Max Ext.Boom for Flexi-I,Pro-Flex Extr.Crane(4,5,6.5),VE Ext.Boom for HoseReels&Hose Drops &VE articulating Crane for HoseDrops (4,5,6)
  • For use only with P-147,P-148, P-149 and P-152 up to P-156 Fans
  • P-151 P-MAX fan mounting bracket c/w swivel. To be used to install a P-Max fan on a H-Max Extension Boom for Flexi-II and E-Z Arm, Pro-Flex Extraction Crane (8" dia.), VE Extension Boom for Hose Reels&Hose Drops (8" dia.) and VE articulating Crane for Hose Drops (8" dia.)
  • For use only with P-147,P-148, P-149, P-152 up to P-156 Fans
  • P-766-HD-GALV Heavy duty galvanized fan mounting bracket w/ hardware to connect fan.
    Installation Accessories
    Part # Description
    PDK-8 Industrial grade duct kit for direct exhausting of P-Max fans - for Wall exhaust c/w the following parts:
  • 2 pcs - 24" - 8" diameter lateral duct -1 pc - 8" diameter long radius elbow -1 pc - 8" exhaust fitting -45 degree weather elbow -backdraft damper -bird screen 16" X 16" exterior wall flashing
  • PDK-RF-8 Industrial grade duct kit for direct exhausting of P-Max fans - for Ceiling/Roof exhaust. Complete with Gravity Back Draft damper.